Inspections for the day of: Monday, December 4, 2017.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-02434 Rough-In Permanent Service12/4/201712/4/201712/4/2017 2:10:56 PMPNR
I''m replacing my panel today and would like an inspection late in the day to make sure I get it all in. Please call ahead to confirm I am ready for inspection. Thanks! 208 841 7286. Phone #: ###-#### Inspection requested via web by Dennis Ahern
Called contact to check on progress and was asked to reschedule for next day in AM due to not being ready.
ELE17-04065 Permanent Service12/4/201712/4/201712/4/2017 2:02:20 PMPPASS
Danny is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen
p/s u/g n ok
ELE17-02732 Electrical Rough-In12/1/201712/4/201712/4/2017 1:31:11 PMPPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
All grid except IT room rough in ok cover
ELE17-03964 Electrical Rough-In12/4/201712/4/201712/4/2017 12:19:53 PMPNR
Justin Hamby Phone #: ###-#### Inspection requested via web by Laurie Hoelscher
Wrong permit called in, this job still has all exterior wall finishes to complete. Called contact he will recall when ready.
ELE17-02322 Final12/4/201712/4/201712/4/2017 10:04:54 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn
Final ok
ELE17-04037 Electrical Rough-In12/3/201712/4/201712/4/2017 9:30:25 AMAPASS
There will be guys there working, Jake is the contact ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clay Morgan
Discussed the use of radio frequency switching to avoid power from one building feeding another and required distance from make and break contacts from gas meter. Attached to BLD 17-01565. Garage and room over garage rough in ok cover
ELE17-03979 Temporary Service12/1/201712/4/201712/4/2017 8:53:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Greg Idsinga
t/s o/h n ok
ELE17-04028 Conference12/1/201712/4/201712/4/2017 8:38:21 AMADONE
As early as possible Monday morning would be appreciated. Thanks. Phone #: ###-#### Inspection requested via web by Matt Frey
Owner has wired rooms in a house in past 2 years. Understands receptacle placement around habitable room. Discussed AFCI protection for bedroom outlets, dedicated 20 amp circuit for bathroom receptacles that shall have no other. Tamper resistant receptacles.