Inspections for the day of: Thursday, December 5, 2013.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE00-03086 ELE-Aging Inspection12/5/201312/5/201312/13/2013 3:57:34 PM DONE
Homeowner said he would call for final
ELE13-03380 Permanent Service12/4/201312/5/201312/5/2013 6:09:23 PMPPASS
Please call AT LEAST 1/2 hour before arriving on job site. Thanks! Phone #: ###-#### >> Inspection requested via web by PAUL PINNEY p/s u/g rec ok
ELE13-03380 Electrical Rough-In12/5/201312/5/201312/5/2013 6:08:30 PMPFAIL
Please call AT LEAST 1/2 hour before arriving on job site. Thanks! Phone #: ###-#### >> Inspection requested via web by PAUL PINNEY NEC 110.3 Manufacture requires GFEP protection for snow melt equipment
ELE13-03357 Permanent Service12/4/201312/5/201312/5/2013 5:59:21 PMPFAIL
We are upgrading the service on this home, I was hoping to get an inspection mid afternoon tomorrow so Idaho Power wont have any issues powering the home back up, please call for details, ###-####, thanks, Terry W. Phone #: ###-#### Phone #: ###-#### >> Inspection requested via web by Stephen Kren NEC 240.24 (A) service height. Overcurrent devices shall be readily accessible an shall be installed so that the center grip of the operating handle of the switch or breaker, when in its highest position,is not more than 6ft 7in. above floor or working platform.
ELE13-02606 Final12/4/201312/5/201312/5/2013 2:07:40 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Celinda Winters final ok
ELE13-03060 Final12/5/201312/5/201312/5/2013 1:25:37 PMPPASS
Final of Walk-in cooler and freezer and rest of project Phone #: ###-#### >> Inspection requested via web by Stan Woodward final ok
ELE13-03382 Electrical Rough-In12/5/201312/5/201312/5/2013 12:52:39 PMPPASS
exterior lighting replacment Phone #: ###-#### >> Inspection requested via web by kendall bender CSA listed HID replacement fixtures, rough-in ok
ELE13-03049 Electrical Rough-In12/5/201312/5/201312/5/2013 12:38:01 PMPPASS
Wall cover. Dan on site Phone #: ###-#### >> Inspection requested via web by Buster Bowen rough-in ok cover walls bathrooms, janitorial room, prep room. As per highlighted (yellow) and dated
ELE13-02942 Electrical Rough-In12/4/201312/5/201312/5/2013 9:47:33 AMAPASS
floor heat inspection Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot rough-in ok cover floor heat
ELE13-03051 Final12/4/201312/5/201312/5/2013 9:38:28 AMAPASS
Owner Robert should be home thanks Phone #: ###-#### >> Inspection requested via web by Brad Baker final ok
ELE13-02902 Final12/4/201312/5/201312/5/2013 9:07:47 AMAPASS
Contact: Justin Hugo Phone #: ###-#### >> Inspection requested via web by Deb Gooden final ok
ELE13-03067 Final12/3/201312/5/201312/5/2013 8:35:57 AMANR
Temporary Occupancy needed. Thank you! Phone #: ###-#### >> Inspection requested via web by Daniel Schaffeld Not ready, panel covers not installed
ELE13-03076 Rough-In Permanent Service12/4/201312/5/201312/5/2013 8:22:43 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Heath Thomas rough-in p/s u/g n ok