Inspections for the day of: Wednesday, December 5, 2018.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-05828 Final12/4/201812/5/201812/5/2018 3:47:08 PMPPASS
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
MEC18-05322 Final12/5/201812/5/201812/5/2018 3:26:44 PMPPASS
Phone #: ###-#### Inspection requested via web by Aaron Alandt
MEC18-04304 Final12/5/201812/5/201812/5/2018 2:56:51 PMPPASS
James Phone #: ###-####
MEC18-05757 Rough-in11/30/201812/5/201812/5/2018 2:29:40 PMPFAIL
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
mini split bath fans and range vent okay, dryer vent needs to be in a 4" wall and brought up to code
MEC18-05814 Final12/4/201812/5/201812/5/2018 1:54:29 PMPPASS
INSTALLER GERRY ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
MEC18-00350 Rough-in12/5/201812/5/201812/5/2018 11:31:58 AMPPASS
1st floor plenum area okay above grid
MEC13-05469 Final12/4/201812/5/201812/5/2018 11:28:41 AMAFAIL
Items that remain for Final:
Set 5 ton condencer on south east corner
all work for outdoor kitchen under this permit will need to be complette, nothing for the out door kitchen has been started yet.
Garage unit heater not installed will need combustion air because of tight construction.
Furnace in garage that serves the kitchen needs condensate piping ran, and filter access addressed.
All missing grilles and thermostates on all floors need to be installed,
Range vent and cook top need to be installed, makeup air for range provided by RTU economizers preset partial open, air balance will show proper fresh air value.
Need Balance and Blast report.
Fan needs to be installed in downstairs furnace room.Duct seal and 2nd condensate drain on furnace.
1st furnace in crawl needs 2nd condensate drain ran. 2nd furnace needs both condensates ran.
MEC18-05251 Pressure Test12/3/201812/5/201812/5/2018 11:07:13 AMAPASS
SHARE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
20lb
MEC18-05251 Final12/5/201812/5/201812/5/2018 11:06:58 AMPPASS
SHARE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC18-05251 Rough-in12/3/201812/5/201812/5/2018 11:06:43 AMAPASS
SHARE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC18-05806 Pressure Test12/4/201812/5/201812/5/2018 9:43:34 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
need to witness flue pressure test
MEC18-05806 Rough-in12/4/201812/5/201812/5/2018 9:43:16 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
need to witness flue pressure test
MEC18-05808 Final12/4/201812/5/201812/5/2018 9:27:41 AMAFAIL
can you please come before 1030am as the customer needs to go to work. please call her on the way her name is Michelle and her # is ###-#### Phone #: ###-#### Inspection requested via web by Marisa Hone
disconnect needs to be in line of site of furnace, need to witness flue pressure test, arma flex needs U.V. protection
MEC18-04387 Final12/4/201812/5/201812/5/2018 9:10:47 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
MEC18-04095 Final12/4/201812/5/201812/5/2018 8:55:25 AMAPASS
Garage code: 4224 Phone #: ###-#### Inspection requested via web by Dan Otero