MEC18-05828
| Final | 12/4/2018 | 12/5/2018 | 12/5/2018 3:47:08 PM | P | PASS |
|
|
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC18-05322
| Final | 12/5/2018 | 12/5/2018 | 12/5/2018 3:26:44 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC18-04304
| Final | 12/5/2018 | 12/5/2018 | 12/5/2018 2:56:51 PM | P | PASS |
|
|
James Phone #: ###-####
|
MEC18-05757
| Rough-in | 11/30/2018 | 12/5/2018 | 12/5/2018 2:29:40 PM | P | FAIL |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt mini split bath fans and range vent okay, dryer vent needs to be in a 4" wall and brought up to code
|
MEC18-05814
| Final | 12/4/2018 | 12/5/2018 | 12/5/2018 1:54:29 PM | P | PASS |
|
|
INSTALLER GERRY ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC18-00350
| Rough-in | 12/5/2018 | 12/5/2018 | 12/5/2018 11:31:58 AM | P | PASS |
|
|
1st floor plenum area okay above grid
|
MEC13-05469
| Final | 12/4/2018 | 12/5/2018 | 12/5/2018 11:28:41 AM | A | FAIL |
|
|
Items that remain for Final: Set 5 ton condencer on south east corner all work for outdoor kitchen under this permit will need to be complette, nothing for the out door kitchen has been started yet. Garage unit heater not installed will need combustion air because of tight construction. Furnace in garage that serves the kitchen needs condensate piping ran, and filter access addressed. All missing grilles and thermostates on all floors need to be installed, Range vent and cook top need to be installed, makeup air for range provided by RTU economizers preset partial open, air balance will show proper fresh air value. Need Balance and Blast report. Fan needs to be installed in downstairs furnace room.Duct seal and 2nd condensate drain on furnace. 1st furnace in crawl needs 2nd condensate drain ran. 2nd furnace needs both condensates ran.
|
MEC18-05251
| Pressure Test | 12/3/2018 | 12/5/2018 | 12/5/2018 11:07:13 AM | A | PASS |
|
|
SHARE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza 20lb
|
MEC18-05251
| Final | 12/5/2018 | 12/5/2018 | 12/5/2018 11:06:58 AM | P | PASS |
|
|
SHARE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
|
MEC18-05251
| Rough-in | 12/3/2018 | 12/5/2018 | 12/5/2018 11:06:43 AM | A | PASS |
|
|
SHARE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
|
MEC18-05806
| Pressure Test | 12/4/2018 | 12/5/2018 | 12/5/2018 9:43:34 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves need to witness flue pressure test
|
MEC18-05806
| Rough-in | 12/4/2018 | 12/5/2018 | 12/5/2018 9:43:16 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves need to witness flue pressure test
|
MEC18-05808
| Final | 12/4/2018 | 12/5/2018 | 12/5/2018 9:27:41 AM | A | FAIL |
|
|
can you please come before 1030am as the customer needs to go to work. please call her on the way her name is Michelle and her # is ###-#### Phone #: ###-#### Inspection requested via web by Marisa Hone disconnect needs to be in line of site of furnace, need to witness flue pressure test, arma flex needs U.V. protection
|
MEC18-04387
| Final | 12/4/2018 | 12/5/2018 | 12/5/2018 9:10:47 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero
|
MEC18-04095
| Final | 12/4/2018 | 12/5/2018 | 12/5/2018 8:55:25 AM | A | PASS |
|
|
Garage code: 4224 Phone #: ###-#### Inspection requested via web by Dan Otero
|