Inspections for the day of: Tuesday, December 6, 2005.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-04074 Conference12/6/200512/6/200512/6/2005 4:11:14 PMPPART
mike; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
talked about service
ELE05-04366 Electrical Rough-In12/5/200512/6/200512/6/2005 2:56:08 PMPNR
SERVICE UPGRADE, SAM WILL BE ON SITE. THANK YOU, ANY QUESTIONS PLEASE CONTACT HIM @ 841.6372; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH
ELE05-04362 Electrical Rough-In12/6/200512/6/200512/6/2005 2:41:20 PMPPASS
mike; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
check for 3 way nto basement on final
ELE05-04377 Electrical Rough-In12/6/200512/6/200512/6/2005 2:26:35 PMPPART
rowdy ###-####
U/G between garage and house
ELE05-03625 Final12/6/200512/6/200512/6/2005 1:24:38 PMPFAIL
spencer; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
several receps require GFCI protection in laundry room and the room next to it within 6 ft of either sink
ELE05-03396 Permanent Service12/6/200512/6/200512/6/2005 1:10:59 PMPPASS
spencer; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
ELE05-04355 Electrical Rough-In12/5/200512/6/200512/6/2005 10:20:49 AMANR
Scheduled by a contractor via Hello! on 12/5/2005 at 10:47:48 AM. Contact: ###-####.
had conf about redundant grounding
ELE05-03312 Final12/5/200512/6/200512/6/2005 10:18:54 AMAFAIL
Scheduled by a contractor via Hello! on 12/5/2005 at 2:14:00 PM. Contact: ###-####.
401.101 (C) track light through walls
ELE05-01103 Electrical Rough-In12/5/200512/6/200512/6/2005 9:26:50 AMAPASS
Scheduled by a contractor via Hello! on 12/5/2005 at 10:53:22 PM. Contact: ###-####.
room count to increase to 10
ELE05-00455 ELE-Aging Inspection12/6/200512/6/200512/6/2005 9:22:21 AM NR
suc
ELE05-04333 Conference12/5/200512/6/200512/6/2005 8:54:48 AMAPART
8:30 am; Phone #: ###-#### Internet Inspection Request from: Dana Moyer
P/S U/G R Ok
check water bond and new circuit to furnace and range top platform and 2nd ground rod on final
ELE05-04362 Electrical Rough-In12/5/200512/6/200512/6/2005 8:51:52 AMANH
mike ###-####enter thru back
doors locked called will reschedual
ELE05-03396 DOC - Permit Finaled12/6/200512/6/200512/6/2005 12:00:00 AMPPASS
spencer; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
ELE05-04366 Permanent Service12/6/200512/6/200512/6/2005 12:00:00 AMPPASS
SERVICE UPGRADE, SAM WILL BE ON SITE. THANK YOU, ANY QUESTIONS PLEASE CONTACT HIM @ 841.6372; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH
P/S O/H R Ok