ELE05-04393
| Electrical Rough-In | 12/6/2005 | 12/6/2005 | 12/6/2005 4:16:15 PM | P | PASS |
|
|
Bonding Inspection ; Phone #: ###-#### Internet Inspection Request from: Cathy Felin pool bond only ok, couldn't check u/g. potting and equipotential plane later
|
ELE05-03438
| Final | 12/6/2005 | 12/6/2005 | 12/6/2005 4:14:11 PM | P | PASS |
|
|
Charlie; Phone #: ###-#### Internet Inspection Request from: Melyne Davis called contr to check dead recpt in exst part of house, ok to final
|
ELE05-03901
| Final | 12/6/2005 | 12/6/2005 | 12/6/2005 3:35:55 PM | P | PASS |
|
|
paul; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
|
ELE05-04390
| Temporary Service | 12/6/2005 | 12/6/2005 | 12/6/2005 2:43:38 PM | P | PASS |
|
|
any questions please call Ed Schallock; Phone #: ###-#### Internet Inspection Request from: Jeff Radford t/s u/g n ok
|
ELE05-04319
| Final | 12/6/2005 | 12/6/2005 | 12/6/2005 1:39:10 PM | P | NR |
|
|
DAN; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy still working on job
|
ELE05-04290
| Electrical Rough-In | 12/6/2005 | 12/6/2005 | 12/6/2005 12:35:55 PM | P | FAIL |
|
|
robert; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr not complete
|
ELE05-04361
| Rough-In Permanent Service | 12/5/2005 | 12/6/2005 | 12/6/2005 10:00:42 AM | A | FAIL |
|
|
bob ###-#### called, left message, left corr notice,312.5 abrasion protection shall be provided for all conductors entering enclosure,300.4(D)nm cable shall be 1 1/4" from edge of framing member,314.16 boxes shall be of sufficient size to provide free space for all enclosed conductors,garage, 314.19 boxes shall be flush to completely cover front light
|
ELE05-03220
| Final | 12/5/2005 | 12/6/2005 | 12/6/2005 9:55:28 AM | A | PASS |
|
|
FINAL INSPECTION READY, OK PER NOTES. GROUND WIRE ADDED. CODE IS 1969 FOR ENTRY. ANY QUESTIONS PLEASE CONTACT CHRIS @ 761.6294; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ok to final
|
ELE05-04276
| Final | 12/5/2005 | 12/6/2005 | 12/6/2005 9:02:31 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called, left message, left corr notice, 312.5 abrasion protectin shall be provided for gec.
|
ELE05-03344
| Final | 12/5/2005 | 12/6/2005 | 12/6/2005 8:39:14 AM | A | FAIL |
|
|
spencer; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called, left corr notice, 210.52(A) shall add recpt in upper east bedroom, 406.4(D) recpts shall be flush or project from faceplates, 110.3(B) recpts shall operate in front room and correct polarity for freezer
|