Inspections for the day of: Thursday, December 6, 2007.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-03463 Final12/6/200712/6/200712/6/2007 4:19:15 PMPNH
mike Phone #: ###-#### called contractor, left sticker, told to call when can get in, told we don't go into occupied house alone, fee due
ELE07-03784 Permanent Service12/6/200712/6/200712/6/2007 3:26:55 PMPPASS
Scheduled by a contractor via Hello! on 12/6/2007 at 10:18:32 AM. Contact: ###-####. correction made, p/s, u/g, n, ok (5 meters)
ELE07-03445 Rough-In Permanent Service12/6/200712/6/200712/6/2007 2:33:59 PMPCANC
Phone #: ###-#### Internet Inspection Request from: Celinda Winters wrong type request, see p/s
ELE07-03445 Permanent Service12/6/200712/6/200712/6/2007 1:52:33 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Celinda Winters p/s o/h n ok
ELE07-01280 Final12/6/200712/6/200712/6/2007 1:51:18 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Justin Yount met contractor, left correction notice, nec 210.52(C)(1) countertop receptacles shall be installed such that 24" spacing is maintained,210.8(A)(3) outdoor receptacles shall be gfci protected, BCC shall install switches for upstairs bath light and fan
ELE07-04025 Electrical Rough-In12/5/200712/6/200712/6/2007 12:43:16 PMPFAIL
sam Phone #: ###-#### met owner, left correction notice, 334.10(A) nm cables shall be permitted for exposed and concealed work in normally dry locations, 410.8 closet light shall be installed to meet clearances over combustible material, BCC all make-up shall be done
ELE06-02307 ELE-Aging Inspection12/6/200712/6/200712/6/2007 10:20:21 AM DONE
see final
ELE06-02307 Final12/6/200712/6/200712/6/2007 10:09:05 AMPPASS
looked at job, met maintenance men, ok to final
ELE07-03831 Conference12/5/200712/6/200712/6/2007 9:56:04 AMADONE
JOE Phone #: ###-#### talked about disconnect locations in kitchen
ELE07-03831 Electrical Rough-In12/6/200712/6/200712/6/2007 9:18:44 AMAPASS
JOE Phone #: ###-#### ok to cover south wall only
ELE07-02985 Final12/5/200712/6/200712/6/2007 8:51:07 AMAPASS
Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ok to final, no card to sign