Inspections for the day of: Thursday, December 6, 2012.
Number of inspections: 29
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD12-03041 BLD-Footing12/6/201212/6/201212/7/2012 10:48:02 AMPPASS
Mike Phone #: ###-####
BLD12-03040 BLD-Footing12/6/201212/6/201212/7/2012 10:47:42 AMPPASS
Mike Phone #: ###-####
BLD12-02745 BLD-Final12/5/201212/6/201212/7/2012 9:19:10 AMADEFR
Phone #: ###-#### >> Inspection requested via web by Greg Kirkes
BLD12-02052 BLD-Final12/5/201212/6/201212/7/2012 9:18:16 AMADEFR
Phone #: ###-#### >> Inspection requested via web by Greg Kirkes
BLD12-01711 BLD-Final12/5/201212/6/201212/7/2012 9:17:31 AMADEFR
Phone #: ###-#### >> Inspection requested via web by Greg Kirkes
BLD12-01631 BLD-Final12/5/201212/6/201212/7/2012 9:16:41 AMADEFR
Phone #: ###-#### >> Inspection requested via web by Greg Kirkes
BLD11-00939 BLD-Final12/5/201212/6/201212/7/2012 9:15:54 AMADEFR
Phone #: ###-#### >> Inspection requested via web by Greg Kirkes
ESC12-00744 Site Preparation12/6/201212/6/201212/6/2012 3:52:00 PMPPASS
BLD12-01919 BLD-Footing12/5/201212/6/201212/6/2012 3:51:42 PMPPASS
Ryan Phone #: ###-####
BLD12-02815 BLD-Final12/6/201212/6/201212/6/2012 3:19:32 PMPPASS
Walter Phone #: ###-####
BLD12-02815 DOC - Permit Finaled12/6/201212/6/201212/6/2012 3:19:14 PMPPASS
BLD10-02507 BLD-Aging Inspection12/6/201212/6/201212/6/2012 2:32:28 PM PASS
BLD10-02507 DOC - Permit Finaled12/6/201212/6/201212/6/2012 2:32:04 PMPPASS
BLD10-02507 BLD-Final12/6/201212/6/201212/6/2012 2:31:54 PMPPASS
BLD12-02274 BLD-Framing/Rough-in12/6/201212/6/201212/6/2012 2:29:10 PMPPART
justin Phone #: ###-#### soffit south p/l not gyp// inside ok to cover.
BLD12-02516 BLD-Final12/6/201212/6/201212/6/2012 2:28:05 PMPDEFR
Call Tim 30 minutes prior for access Phone #: ###-#### >> Inspection requested via web by Timothy Gammill
ESC12-01008 Random Inspection12/6/201212/6/201212/6/2012 2:23:30 PMPPASS
BLD12-02681 BLD-Energy code compliance12/6/201212/6/201212/6/2012 2:22:53 PMPPASS
vince Phone #: ###-####
BLD12-02450 BLD-Final11/30/201212/6/201212/6/2012 2:12:44 PMPPASS
John Clampett ###-####
BLD12-02274 BLD-Energy code compliance12/6/201212/6/201212/6/2012 1:42:22 PMPPASS
justin Phone #: ###-####
BLD12-02259 BLD-Conference12/5/201212/6/201212/6/2012 12:30:07 PMANH
Phone #: ###-#### >> Inspection requested via web by Greg Kirkes
BLD12-02613 BLD-Final12/3/201212/6/201212/6/2012 12:27:12 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Frederick Sand
BLD12-02613 DOC - Permit Finaled12/6/201212/6/201212/6/2012 12:26:59 PMPPASS
BLD10-02844 BLD-Final12/3/201212/6/201212/6/2012 12:25:50 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Frederick Sand
BLD10-02844 DOC - Permit Finaled12/6/201212/6/201212/6/2012 12:25:34 PMPPASS
BLD12-01659 BLD-Energy code compliance12/5/201212/6/201212/6/2012 12:24:01 PMAPASS
Chad Phone #: ###-####
BLD12-01659 BLD-Framing/Rough-in12/5/201212/6/201212/6/2012 12:23:42 PMAPASS
Chad Phone #: ###-####
BLD12-01813 BLD-Footing12/3/201212/6/201212/6/2012 12:11:03 PMACANC
mike Phone #: ###-####
BLD12-02231 BLD-Framing/Rough-in12/4/201212/6/201212/6/2012 11:11:42 AMAPART
Jason Phone #: ###-#### roof deck ok to cover/ need truss engineering to justfy jack bearing point to wall south side of hip/