Inspections for the day of: Friday, December 6, 2013.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
GCE13-00082 GCE-Final12/6/201312/6/201312/9/2013 9:03:45 AMPPASS
###-#### Final ok
ELE12-01043 ELE-Aging Inspection12/6/201312/6/201312/9/2013 8:24:56 AM CANC
too busy
ELE12-01289 ELE-Aging Inspection12/6/201312/6/201312/9/2013 8:24:25 AM CANC
too busy
ELE13-02835 Rough-In Permanent Service12/6/201312/6/201312/6/2013 5:12:56 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Alan Lusk 200.6- All grounded conductors at service shall be identified.
300.4- NM cables ran through bored holes less than 1 1/4" from framing surface shall be protected from physical damage.
334.15(B)- NM cable in kitchen ablove 3 gang not contained with in stud bay.
334.30- NM cable shall be secured with in 4 1/2' of passing through verital hole and with 12" of boxes. S/L to out soffit cans, spare bed, spare bath.
ELE13-03381 Permanent Service12/6/201312/6/201312/6/2013 4:24:41 PMPPASS
p/s o/h rec ok
ELE13-02207 Final12/6/201312/6/201312/6/2013 4:01:10 PMPPASS
Swimming pools Phone #: ###-#### >> Inspection requested via web by Lars Johnson Final ok
ELE13-03396 Electrical Rough-In12/6/201312/6/201312/6/2013 2:42:06 PMPPASS
Warren Phone #: ###-#### Wall rough in ok cover
ELE13-02719 Final12/6/201312/6/201312/6/2013 2:05:09 PMPPASS
Key in mail box at front door. Phone #: ###-#### >> Inspection requested via web by Alan Lusk Final ok
ELE13-03379 Electrical Rough-In12/5/201312/6/201312/6/2013 1:33:19 PMAPASS
Please let me know if there are any problems. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan Garage rough in ok cover
ELE13-03195 Electrical Rough-In12/5/201312/6/201312/6/2013 1:08:04 PMAPASS
Floor heat inspection Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot Rough in ok cover
ELE13-03203 Final12/5/201312/6/201312/6/2013 12:29:06 PMAPASS
This is ready to final thanks Dave Phone #: ###-#### >> Inspection requested via web by jason shifflett Final ok
ELE13-03203 Final12/5/201312/6/201312/6/2013 12:28:06 PMAPASS
This is ready to final thanks Dave Phone #: ###-#### >> Inspection requested via web by jason shifflett Final ok
ELE13-02725 Conference12/2/201312/6/201312/6/2013 12:11:24 PMADONE
Conference - Angie Phone #: ###-#### Basement to remain unfinished and completed at future date. Discussed required bath receptical circuits shall have no other, arc fault protection, closet light clearences, unfinished basements.
ELE13-02931 Final12/6/201312/6/201312/6/2013 11:01:55 AMPCANC
Phone #: ###-#### >> Inspection requested via web by John VanZandt Inspection cancelled from web by: John VanZandt
ELE13-02788 Final12/3/201312/6/201312/6/2013 10:37:17 AMAPASS
Contact: Josh Mangum, please call 1/2 hour before going so he can meet you there. Phone #: ###-#### >> Inspection requested via web by Deb Gooden Corrections complete. Panels listed with out covers as per UL-1286. Final ok
ELE13-02791 Final12/5/201312/6/201312/6/2013 10:08:25 AMAPASS
Final inspection for Woodland Brewery. Please call Rod Tomlinson at ###-#### Phone #: ###-#### >> Inspection requested via web by Clint Tate Final ok
ELE13-03049 Electrical Rough-In12/5/201312/6/201312/6/2013 9:49:17 AMAPASS
Ceiling cover. Dan Lowry on site Phone #: ###-#### >> Inspection requested via web by Buster Bowen Hard lids rough in ok cover
ELE13-03174 Final12/5/201312/6/201312/6/2013 9:37:18 AMAPASS
CELL ###-#### Phone #: ###-#### >> Inspection requested via web by Mark M Final ok
GCE13-00180 GCE-Final12/5/201312/6/201312/6/2013 9:05:20 AMAPASS
Alan ###-#### Final ok
GCE13-00183 GCE-Final12/5/201312/6/201312/6/2013 8:47:21 AMAPASS
Jim ###-#### No card posted Final ok
ELE13-01001 Electrical Rough-In12/5/201312/6/201312/5/2013 2:53:19 PMACANC
Phone #: ###-#### >> Inspection requested via web by Mark M Inspection cancelled from web by: Mark M