Inspections for the day of: Wednesday, December 7, 2005.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01232 ELE-Aging Inspection12/7/200512/7/200512/12/2005 1:46:18 PM DONE
ELE05-03604 ELE-Aging Inspection12/7/200512/7/200512/7/2005 3:50:26 PM NR
no power yet cannot check for final
ELE05-04402 Final12/6/200512/7/200512/7/2005 3:46:30 PMPPASS
We installed 2 new GFCI protected outdoor soffet receptacles and tied them into the existing outdoor light so they are controlled by the same switch. The 1st receptacle is to the right of the northmost overhead garage door in the soffet(this is the GFCI that protects both), the 2nd receptacle is in the house soffet near the southeast corner of the house. This is all outdoors on the driveway side of the house so you won't need to meet with the owner. THANKS !!! Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
ELE05-04405 Rough-In Permanent Service12/6/200512/7/200512/7/2005 3:25:29 PMPPART
We are upgrading the service to 200 amps on the exterior of the house and are replacing the indoor panel also. Idaho Power is killing the power in the AM so we can do this work and we will need you to inspect in the PM so they will re-energize. We will call you when we are done or you can call us when you have time to head that way. THANKS !!!! Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell cor. called 250.52,104(A)(1) grd or bond water system 250.66 shall be #4 copper p/s o/h rec. ok
ELE05-04416 Permanent Service12/7/200512/7/200512/7/2005 2:50:18 PMPPASS
bryan ###-#### p/s o/h rec. ok
ELE04-03054 Electrical Rough-In12/7/200512/7/200512/7/2005 2:16:12 PMPPART
ROUGH-IN INSPECTION FOR POOL FIXTURES. THANKS; Phone #: ###-#### Internet Inspection Request from: Barry Kendall potting ok
ELE05-04315 Final12/6/200512/7/200512/7/2005 1:19:23 PMPFAIL
Todd, ###-#### - pls call 30 minutes prior cor. posted 250.148 (C) shall terminate all equip grds together and grd box, remove all abandoned cables ( low votage)
ELE05-03283 Final12/6/200512/7/200512/7/2005 12:27:50 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Dan Rohl ok survey posted called
ELE05-02785 Electrical Rough-In12/6/200512/7/200512/7/2005 11:59:09 AMAPASS
Scheduled by a contractor via Hello! on 12/6/2005 at 9:47:45 PM. ok
ELE05-04398 Rough-In Permanent Service12/6/200512/7/200512/7/2005 10:16:54 AMAPASS
darrell ###-#### r/i ok p/s o/h new ok
ELE05-04361 Rough-In Permanent Service12/6/200512/7/200512/7/2005 9:54:21 AMAPASS
bob; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles r/i ok
p/s u/g new ok
ELE05-04367 Permanent Service12/6/200512/7/200512/7/2005 9:15:30 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Dana Moyer cor. fee due, met contractor, 250.92(A)(3) shall bond both ends where GEC is in metal 312,5 needs conn for GEC314.28 needs bigger J box bottom of p/s,310.15(B)(6) needs 2/0 to each meter base300.10 bond bushings where RE washers are used, 250.66 all GEC abd main bonds shall be #2 copper 250.148 splice all equip grds together and tap box top of p/s110.3(A) shall replace damaged bus from arcing effects right side p/s panel replace all splices and terminations where wire is ringed from stripping
ELE05-03772 Electrical Rough-In12/7/200512/7/200512/7/2005 12:00:00 AMANR
nr Jim Schmer is checking job if owner is allowed to have permit, not there primary residence move in house and new garage with apartment on second floor
ELE05-04416 Final12/7/200512/7/200512/7/2005 12:00:00 AMPPASS
bryan ###-#### ok