PLM15-04088
| Plumbing Rough-in | 12/4/2015 | 12/7/2015 | 12/7/2015 4:25:25 PM | P | FAIL |
|
|
JOB # 18303. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes >DWV test failed >vent needs to be rolled on tub upstairs >tail piece to trap on tub is under stress from vent pipe.>fix stub out on hall bath lav.
|
PLM15-04186
| Water Heater Final | 12/7/2015 | 12/7/2015 | 12/7/2015 3:59:12 PM | P | FAIL |
|
|
Casey Phone #: ###-#### >T&P needs to terminate outside >provide combustion air
|
PLM15-03889
| Plumbing Rough-in | 12/4/2015 | 12/7/2015 | 12/7/2015 2:57:16 PM | P | PASS |
|
|
Christine and Gary Reynolds ###-#### Phone #: ###-#### Inspection requested via web by Chris Field
|
PLM15-04182
| Plumbing Rough-in | 12/6/2015 | 12/7/2015 | 12/7/2015 2:33:18 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Scott Hurren
|
PLM15-04107
| Final | 12/2/2015 | 12/7/2015 | 12/7/2015 2:11:56 PM | P | FAIL |
|
|
CALL KODY WITH ANY QUESTIONS OR CONCERNS ###-#### Phone #: ###-#### Inspection requested via web by Ben Davis >t&p discharge at outside needs to turn down.
|
PLM15-02801
| PLM-Aging Inspection | 12/7/2015 | 12/7/2015 | 12/7/2015 2:10:48 PM | | FAIL |
|
|
no calls
|
PLM15-04188
| Final | 12/7/2015 | 12/7/2015 | 12/7/2015 1:42:02 PM | P | PASS |
|
|
mobile home hook-up; Tarry Phone #: ###-####
|
PLM15-04189
| Final | 12/7/2015 | 12/7/2015 | 12/7/2015 1:37:05 PM | P | PASS |
|
|
mobile home hook-up; Tarry Phone #: ###-####
|
PLM15-03719
| Groundwork | 12/7/2015 | 12/7/2015 | 12/7/2015 1:18:38 PM | P | PART |
|
|
DAVID IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER > grease gw ok to cover in detail shop >grease gw ok to cover on east side of service bays
|
PLM15-04177
| Water and/or Sewer | 12/4/2015 | 12/7/2015 | 12/7/2015 11:16:40 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brent Lacy
|
PLM15-04170
| Plumbing Rough-in | 12/4/2015 | 12/7/2015 | 12/7/2015 10:42:52 AM | A | PASS |
|
|
Juan Phone #: ###-####
|
PLM15-04183
| Plumbing Rough-in | 12/7/2015 | 12/7/2015 | 12/7/2015 10:01:18 AM | A | PEND |
|
|
Key is under paver by front door Phone #: ###-#### Inspection requested via web by Boe Jares >>>>Tub spout rough looks to low to have a 1β airgap when spout is installed. Verify before sheetrock. Top of tub to center of pipe is 2 ΒΌβ.
|
PLM15-04178
| Water Softner Final | 12/4/2015 | 12/7/2015 | 12/7/2015 9:54:17 AM | A | FAIL |
|
|
water softener install. Homeowner requests am appointment. Please call when en route ###-#### Phone #: ###-#### Inspection requested via web by JEREMY LINK >P-trap installed for softener drain does not meet code, santee for vertical use only and trap must be vented. >softener drain needs a 1β airgap
|