Inspections for the day of: Wednesday, December 7, 2016.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC16-05428 Final12/6/201612/7/201612/7/2016 4:25:05 PMPPASS
early pm inspection please
installer: sam ###-####
Thank you Phone #: ###-#### Inspection requested via web by Dustin Rich
MEC16-05437 Pressure Test12/6/201612/7/201612/7/2016 3:47:53 PMPPASS
JEREMY IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- 60lb gas pass from meter bar location to 3rd floor bbqs- P1.11M and P1.12 drawings- this addition needs to be submitted to city as its not on approved drawing- talked to Bill and Troy about this- they are using this gas line for temporary heat for now
MEC16-02105 Mec-Aging Inspection12/7/201612/7/201612/7/2016 2:44:19 PM DONE
MEC16-02105 DOC - Permit Expired12/7/201612/7/201612/7/2016 2:44:02 PMPPASS
work never done-
MEC16-05436 Rough-in12/7/201612/7/201612/7/2016 2:43:30 PMPPASS
MEC16-02105 DOC - Permit Expired12/7/201612/7/201612/7/2016 2:22:49 PMPPASS
did not do w/h install
MEC16-04740 Pressure Test12/7/201612/7/201612/7/2016 2:00:15 PMPPASS
20lb gas pass
MEC16-04740 Rough-in12/1/201612/7/201612/7/2016 1:59:25 PMPFAIL
Rough in and pressure test Phone #: ###-#### Inspection requested via web by Diane Day- flue pressure at 4lbs- b vent needs 1" clearance to combustibles in attic and water heater alcove- insulation shield needs fixed on b vent at water heater alcove- left notice on back window
MEC15-03353 Mec-Aging Inspection12/7/201612/7/201612/7/2016 12:08:55 PM CANC
no call- will expire permit next time comes up on aging
MEC16-05426 Final12/6/201612/7/201612/7/2016 11:53:48 AMAPASS
This is for late AM please call Jarod B4 arrival to arrange time and access Phone #: ###-#### Inspection requested via web by Dustin Rich
MEC16-00737 Mec-Aging Inspection12/7/201612/7/201612/7/2016 10:55:10 AM PASS
MEC16-00737 Final12/7/201612/7/201612/7/2016 10:54:45 AMPPASS
MEC16-03905 Final12/6/201612/7/201612/7/2016 10:36:28 AMAPASS
Call Jason with any issues at 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
MEC15-03325 Mec-Aging Inspection12/7/201612/7/201612/7/2016 10:22:46 AM PASS
MEC15-03325 Final12/7/201612/7/201612/7/2016 10:22:34 AMPPASS
MEC16-05436 Rough-in12/6/201612/7/201612/7/2016 9:33:12 AMAFAIL
DIRK ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson- needs insulation shield for b vent in attic- left correction notice on fireplace
MEC16-05392 Final12/6/201612/7/201612/7/2016 8:47:18 AMAPASS
Please inspect from 8:15 to 11. Homeowner is Jennifer Fuss, ###-####. She has to take kids to school at 8 then leave for work at 11 AM. Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC16-05265 Pressure Test12/6/201612/7/201612/6/2016 1:45:33 PMACANC
Phone #: ###-#### >> Inspection requested via web by Nicholas Paige Inspection cancelled from web by: Nicholas Paige