Inspections for the day of: Monday, December 8, 2003.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-00422 ELE-Aging Inspection12/8/200312/8/200312/8/2003 12:00:00 AM DONE
done by plass 12/9/2003 12:04:12 PM
ELE03-00597 ELE-Aging Inspection12/8/200312/8/200312/8/2003 12:00:00 AM DONE
ELE03-01340 ELE-Aging Inspection12/8/200312/8/200312/8/2003 12:00:00 AM PASS
ok 12/9/2003 9:06:17 AM
ELE03-02829 Electrical Rough-In12/5/200312/8/200312/8/2003 12:00:00 AMAPART
Daniel; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes walls and hard ceilings ok 12/8/2003 9:19:30 AM
ELE03-03604 Electrical Rough-In12/5/200312/8/200312/8/2003 12:00:00 AMAPART
Paul; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes u/g ok 12/8/2003 11:37:13 AM
ELE03-03821 Rough-In Permanent Service12/2/200312/8/200312/8/2003 12:00:00 AMAFAIL
steve- ###-#### 210.52(C) outlet left of kitchen sink shall face into kit in backsplash called left message 12/8/2003 10:03:32 AM
ELE03-02528 Final12/5/200312/8/200312/8/2003 12:00:00 AMAPASS
CONTACT SHANE KORTE ; Phone #: ###-#### Internet Inspection Request from: Deb McCoy ok 12/8/2003 8:31:01 AM
ELE03-03821 Permanent Service12/8/200312/8/200312/8/2003 12:00:00 AMAPASS
p/s u/g new ok
ELE03-03295 Final12/8/200312/8/200312/8/2003 12:00:00 AMPPASS
Doug --- would like late afternoon if possible.thanks.; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes ok 12/8/2003 3:39:27 PM
ELE03-02125 Electrical Rough-In12/5/200312/8/200312/8/2003 12:00:00 AMPPART
CONTACT DUANE HEINRICHS ROUGH WALL INSPECTION; Phone #: ###-#### Internet Inspection Request from: Deb McCoy
2nd floor walls and hard ceilings 12/8/2003 4:17:21 PM
ELE03-03372 Final12/5/200312/8/200312/8/2003 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 12/5/2003 at 4:23:20 PM. Contact: ###-####. ok 12/8/2003 3:39:47 PM
ELE03-03533 Final12/5/200312/8/200312/8/2003 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 12/5/2003 at 4:25:14 PM. Contact: ###-####. ok 12/8/2003 3:39:16 PM
ELE03-02311 Final12/5/200312/8/200312/8/2003 12:00:00 AMPPASS
Lonny; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes ok 12/8/2003 3:39:37 PM
ELE03-02299 Final12/8/200312/8/200312/8/2003 12:00:00 AMPFAIL
Butch ###-#### cor. posted called 362.12(10) remove or protect ENT front desk, provide bushings where cables pass through alum in power doors, 300.3(C) high and low voltage wiring mixed together in doors, 110.2,110.3 doors shall be listed and approved 12/8/2003 1:56:33 PM