Inspections for the day of: Thursday, December 8, 2016.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM16-01814 PLM-Aging Inspection12/8/201612/8/201612/12/2016 11:14:54 AM PEND
Tagged house to call.
PLM15-04378 DOC - Permit Finaled12/8/201612/8/201612/8/2016 4:09:38 PMPPASS
PLM16-00737 PLM-Aging Inspection12/8/201612/8/201612/8/2016 3:44:12 PM PEND
Tagged 12/8/16 to call cell with status
PLM16-04451 Water Heater Final12/8/201612/8/201612/8/2016 3:25:27 PMPNR
Please call Bob at ###-#### prior to inspection Phone #: ###-#### Inspection requested via web by Tami Kelly
PLM16-04451 Other12/8/201612/8/201612/8/2016 3:24:51 PMPPART
gas pressure test. 20# test ok
PLM16-02489 Water and/or Sewer12/8/201612/8/201612/8/2016 3:12:01 PMPPASS
Fixing correction notice list please come later in pm Phone #: ###-#### Inspection requested via web by Mark Kelso
PLM16-02489 DOC - Permit Finaled12/8/201612/8/201612/8/2016 3:11:33 PMPPASS
PLM16-03755 Plumbing Rough-in12/7/201612/8/201612/8/2016 2:34:55 PMPFAIL
RE-INSPECTION Phone #: ###-#### Inspection requested via web by Ann Marie Reyes. See correction notice from 12/7
PLM16-03956 Plumbing Rough-in12/7/201612/8/201612/8/2016 2:33:38 PMPFAIL
50376 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes.
No repairs have been made.
PLM16-04437 Plumbing Rough-in12/8/201612/8/201612/8/2016 2:33:38 PMPFAIL
Phone #: ###-#### Inspection requested via web by Aarin Van Curen.
DWV test failed.
DWV in crawl backgrading. Correct to 1/4"/ft.
Water test ok
PLM16-03999 Plumbing Rough-in12/7/201612/8/201612/8/2016 1:17:48 PMPPASS
PLM16-04369 Water and/or Sewer12/8/201612/8/201612/8/2016 12:41:58 PMPPART
Phone #: ###-####. New double check valve needs certified
PLM16-03174 Final12/7/201612/8/201612/8/2016 11:46:36 AMAPASS
Lock box code is 2730.
Thank you. Phone #: ###-#### Inspection requested via web by Ken Duplex
PLM16-03959 Final12/7/201612/8/201612/8/2016 11:19:14 AMAPASS
Phone #: ###-#### Inspection requested via web by Branden Steers
PLM16-03868 Final12/7/201612/8/201612/8/2016 11:12:59 AMAPASS
Phone #: ###-#### Inspection requested via web by Branden Steers
PLM16-04451 Other12/8/201612/8/201612/8/2016 10:54:29 AMANR
Gas pressure. Will be ready later in the morning. Please call Bob at ###-#### prior to inspection Phone #: ###-#### Inspection requested via web by Tami Kelly
PLM16-02489 Final12/7/201612/8/201612/8/2016 10:53:29 AMAFAIL
Final Inspection owner is Wong 2088908135 Phone #: ###-#### Inspection requested via web by Mark Kelso. 1. Install a tempering valve on the water heater to control the pedicure sinks.
2. Install a thermal expansion tank on the water heater.
3. Mechanically support the backflow assemblies per plans.
4. 1" RP is discharging.
5. Grade air gap lines from the backflow assemblies.
6. Provide a 1" airgap on the T&P drain.
7. Provide a tempering valve on the pedicure area hand sink.
8. Support drains on the pedicure chair drains.
PLM16-04446 Water Heater Final12/7/201612/8/201612/8/2016 9:39:30 AMAFAIL
water on floor around the water heater.
T&P drain tube is wet inside.
Strap the pex water line ridgid to the wall.
Ensure the pressure tank is pressurized to manufacturers instructions.
PLM16-04197 Plumbing Rough-in12/8/201612/8/201612/8/2016 7:23:55 AMAPART
top out of waste and water for the floral area.
PLM16-04197 Groundwork12/8/201612/8/201612/8/2016 7:22:55 AMAPART
Combination waste and vent underground to the floral area.