Inspections for the day of: Thursday, December 9, 2004.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE04-02976 Final12/9/200412/9/200412/9/2004 10:52:55 AMPCANC
allan; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Inspection cancelled from web by: Barbara Moore
ELE04-02749 Final12/8/200412/9/200412/9/2004 12:00:00 AMAFAIL
Justin; Phone #: ###-#### Internet Inspection Request from: Jan Rice locked out of half of bldg and other half no power to outlets. Will fix and recall. 12/9/2004 8:20:33 AM
ELE04-03856 Electrical Rough-In12/8/200412/9/200412/9/2004 12:00:00 AMANH
Phone #: ###-#### Internet Inspection Request from: Jan Rice no entry, called contr, will recall. 12/9/2004 8:40:30 AM
ELE04-03814 Rough-In Permanent Service12/8/200412/9/200412/9/2004 12:00:00 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Bob Glenn asked elect to see about using stack-it type looms in some places . ok to cover. p/s u/g n ok 12/9/2004 10:07:46 AM
ELE04-03490 Final12/9/200412/9/200412/9/2004 12:00:00 AMAPASS
Internet Inspection Request from: Bob Glenn ok to final 12/9/2004 9:22:55 AM
ELE04-03491 Final12/9/200412/9/200412/9/2004 12:00:00 AMAPASS
Internet Inspection Request from: Bob Glenn ok to final 12/9/2004 9:42:34 AM
ELE04-03464 Electrical Rough-In12/9/200412/9/200412/9/2004 12:00:00 AMPPART
Walls; Phone #: ###-#### Internet Inspection Request from: Jim Williams ok to cover hard lid and walls except phone office area. 12/9/2004 2:11:09 PM
ELE04-03853 Permanent Service12/9/200412/9/200412/9/2004 12:00:00 AMPPASS
late afternoon please and please call prior to inspection steve; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok to final 12/9/2004 4:29:43 PM
ELE04-03856 Electrical Rough-In12/9/200412/9/200412/9/2004 12:00:00 AMPFAIL
inspection for cover please///glenn; Phone #: ###-#### Internet Inspection Request from: Barbara Moore 348.26 there shall not be more than 360 degrees bend in cnd, 250.126 ground screws to be green, 800.52 (B) abandoned cables shall be removed. 12/9/2004 1:06:05 PM
ELE04-03862 Permanent Service12/9/200412/9/200412/9/2004 12:00:00 AMPFAIL
Phone #: ###-#### Internet Inspection Request from: Dan Rohl called contr and left message--- no address, no job id, no plans 12/9/2004 3:14:28 PM
ELE00-04194 Final12/9/200412/9/200412/9/2004 12:00:00 AMPPASS
this permit is really not finalled yet....please call when you arrive so he can meet ya there joe ###-#### ok to final 12/9/2004 12:16:01 PM