Inspections for the day of: Friday, December 9, 2011.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02103 Final12/9/201112/9/201112/9/2011 3:13:05 PMPPASS
Inspect all of the Kitchen, Living Room, Front Room. I just realized I forgot to reinstall two lights on the garage after the siding was changed. Please inspect PM so I can have time to get those installed. Phone #: ###-#### >> Inspection requested via web by nathan palmer ok final
ELE11-02229 Permanent Service12/8/201112/9/201112/9/2011 2:25:50 PMPPASS
Toby Phone #: ###-#### >> Inspection requested via web by Sean DeLacy p/s u/g n ok NOTE; contractor shall verify available fault current from IPCO
ELE11-02554 Electrical Rough-In12/8/201112/9/201112/9/2011 1:33:26 PMPFAIL
don please call before going out- Phone #: ###-#### called, left correction notice, NEC 300.14 shall provide 6" free conductor at box, 250.86 shall provide ground screw in metal boxes, 300.4(A)(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing member, 314.16 shall not exceed box fill, 334.30 shall staple nm within 12" of box or314.17(C) shall staple nm within 8" if more than 1 nm enters box, BCC all make-up shall be done
ELE11-02772 Permanent Service12/9/201112/9/201112/9/2011 12:47:52 PMPNR
Phone #: ###-#### >> Inspection requested via web by John VanZandt talked about concrete encased electrode not being deep enough or ground rods, and to recall
ELE11-02767 Temporary Service12/9/201112/9/201112/9/2011 10:25:22 AMAPASS
THANKS, HAVE A GOOD WEEKEND! BOB Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
ELE11-00639 Final12/7/201112/9/201112/9/2011 10:01:35 AMAPASS
Rocky Phone #: ###-#### ok final
ELE11-01792 Final12/8/201112/9/201112/9/2011 8:42:13 AMAPART
temporary occupancy UL listing has been found Phone #: ###-#### >> Inspection requested via web by Daniel Schaffeld east part done, left correction notice stating BCC4-05-33(A)(B) shall provide listing within 30 days for led lighting and tv stand or that further action will be taken such as removal of power from building, no card to sign for temp occ
ELE11-01515 Electrical Rough-In12/7/201112/9/201112/9/2011 7:56:28 AMANR
Contact: Brian Giacomino - Partial final inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden still wiring, wanted pm inspection