Inspections for the day of: Tuesday, December 9, 2014.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-03328 Permanent Service12/8/201412/9/201412/9/2014 2:45:05 PMPPASS
Please Call Gerald @###-#### To Gain Access To The Residence. We made All The Corrections And its ready To Energize Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett p/s u/g rec ok
ELE14-03328 Final12/9/201412/9/201412/9/2014 2:34:09 PMPPASS
Please Call Gerald @###-#### To Gain Access To The Residence. We made All The Corrections And its ready To Energize Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett Service reconnect Final ok
ELE14-03363 Rough-In Permanent Service12/9/201412/9/201412/9/2014 1:49:28 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok cover p/s u/g n ok
GCE14-00172 GCE-Final12/9/201412/9/201412/9/2014 12:59:27 PMPPASS
Karl ###-#### Final ok
ELE14-03233 Permanent Service12/9/201412/9/201412/9/2014 12:22:13 PMPPASS
INSPECTION IS REQUESTED BY POWER COMPANY - PLEASE INSPECT THIS MORNING IF POSSIBLE. Phone #: ###-#### Inspection requested via web by PAUL PINNEY p/s o/h rec ok
ELE14-03233 Final12/9/201412/9/201412/9/2014 12:21:56 PMPPASS
INSPECTION IS REQUESTED BY POWER COMPANY - PLEASE INSPECT THIS MORNING IF POSSIBLE. Phone #: ###-#### Inspection requested via web by PAUL PINNEY Service reconnect final ok
ELE14-03380 Electrical Rough-In12/8/201412/9/201412/9/2014 10:53:51 AMAPASS
HP is Journeyman contact. Phone #: ###-#### Inspection requested via web by Tyler Bowen Exploritorium walls rough in ok cover
ELE14-02802 Final12/8/201412/9/201412/9/2014 10:08:45 AMAPASS
Inspection requested via web by HZ ZAHIC Final ok
ELE14-03253 Final12/8/201412/9/201412/9/2014 9:31:29 AMAFAIL
Spoke with owner would like to meet around 9 am tues morning. suzanne ###-#### for service upgrade add panel 200.7- Conductor marked as grounded conductor used as ungrounded conductor for water heater shall be other than white or green.
300.4- holes bored less than 1 1/4" from framing surface shall have nail plates to protect NM cable from damage above panel.
422.31(B)- Water heater shall have disconnecting means. Breaker lockout acceptable.
Left correction noticeand called contractor
ELE14-03253 Permanent Service12/9/201412/9/201412/9/2014 9:23:49 AMPPASS
Spoke with owner would like to meet around 9 am tues morning. suzanne ###-#### for service upgrade add panel p/s u/g rec ok
ELE14-03378 Electrical Rough-In12/8/201412/9/201412/9/2014 8:32:30 AMAPASS
Call for lock box code if no one is there Phone #: ###-#### Inspection requested via web by robert feller Wall rough in ok cover