Inspections for the day of: Friday, December 9, 2016.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM16-03284 Final12/9/201612/9/201612/9/2016 5:20:02 PMPPASS
Please call Bridget @ ###-#### for garage code if needed. Phone #: ###-#### Inspection requested via web by Brett Lee
PLM16-03627 Final12/9/201612/9/201612/9/2016 4:39:42 PMPPASS
Phone #: ###-#### Inspection requested via web by Jason Gonzalez
PLM16-04499 Final12/9/201612/9/201612/9/2016 3:54:35 PMPPASS
PLM16-04499 Water and/or Sewer12/9/201612/9/201612/9/2016 3:54:02 PMPPASS
Sewer line install on exterior, front to addition on side yard. Tie into exisitng building sewer on customer property to addition, approximately 60'' total run. Phone #: ###-#### Inspection requested via web by Scott Sparrell
PLM16-03956 Plumbing Rough-in12/8/201612/9/201612/9/2016 3:21:30 PMPPASS
JOB # 50376. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM16-03755 Plumbing Rough-in12/8/201612/9/201612/9/2016 3:19:09 PMPPASS
50319 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM16-03713 Plumbing Rough-in12/8/201612/9/201612/9/2016 3:11:14 PMPFAIL
JOB # 50331. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes. defective waste gauge. I let all the air out and needle never moved.
MIS16-00378 PLM-Conference12/8/201612/9/201612/9/2016 2:39:03 PMPPEND
Leah Phone #: ###-####.1. Install a 3/4" RP backflow assembly on the ice machine/filtered water.
2. Confirm all filtered water is has backflow protection.
3. Repair or replace defective faucet in the Men's room.
4. Install thermostic valve on all lavatory faucets.
5. Cap all unused gas lines.
6. Replace the defective thermal expansion tank on the water heater.
7. Have all backflow assemblies certified.
8. Remove the unused RP backflow assembly in the kitchen.
PLM16-04018 Final12/9/201612/9/201612/9/2016 2:22:50 PMPPASS
PLM16-04018 Water and/or Sewer12/9/201612/9/201612/9/2016 2:22:21 PMPPASS
sewer service air test Phone #: ###-#### Inspection requested via web by Robert Irusta
PLM16-03850 Groundwork12/9/201612/9/201612/9/2016 12:35:41 PMPPASS
Grease trap and duplex grinder ejection system.
PLM16-03850 Other12/8/201612/9/201612/9/2016 12:35:08 PMAPASS
Please send Dan to our location. Phone #: ###-#### Inspection requested via web by Todd Walter
PLM16-04491 Plumbing Rough-in12/8/201612/9/201612/9/2016 11:45:58 AMAPASS
Phone #: ###-#### Inspection requested via web by Brian Johansen
PLM16-04486 Plumbing Rough-in12/8/201612/9/201612/9/2016 11:27:36 AMAPASS
Homeowner will be home in the a.m.

We moved the washer box in the laundry room, added a laundry sink and urinal in the garage that was added on.

Thank you!

Troy Woolston Phone #: ###-#### Inspection requested via web by Troy Woolston****Dan will you make sure the plans show the restroom in the garage-I dob't think it was****
PLM16-04497 Final12/9/201612/9/201612/9/2016 10:14:21 AMAPASS
water service
PLM16-04497 Water and/or Sewer12/8/201612/9/201612/9/2016 10:13:26 AMAPASS
Phone #: ###-#### Inspection requested via web by Frank Young
PLM16-03627 Final12/8/201612/9/201612/9/2016 8:33:03 AMACANC
Phone #: ###-#### >> Inspection requested via web by Jason Gonzalez Inspection cancelled from web by: Jason Gonzalez