ELE06-04068
| ELE-Aging Inspection | 2/1/2007 | 2/1/2007 | 2/1/2007 3:15:49 PM | P | DONE |
|
|
talked with contractor still waiting for response
|
ELE07-00359
| Permanent Service | 2/1/2007 | 2/1/2007 | 2/1/2007 2:48:00 PM | P | FAIL |
|
|
alan ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith no correction posted called need access to inside of house, noted to contr. B C C no violations to be retained, use manufactures listed breakers only, shall not ID 6 or smaller neutral told contr to check p/s out and wire to 2005 NEC
|
ELE06-03350
| Final | 2/1/2007 | 2/1/2007 | 2/1/2007 1:54:55 PM | P | PASS |
|
|
Thank you - On site journeyman Randy ###-####. Phone #: ###-#### ok corrections made, closet fixtures clearence ok
|
ELE07-00362
| Rough-In Permanent Service | 2/1/2007 | 2/1/2007 | 2/1/2007 1:35:34 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 2/1/2007 at 10:01:34 AM. Contact: ###-####. p/s u/g for new meter ok
|
ELE07-00094
| Final | 2/1/2007 | 2/1/2007 | 2/1/2007 12:59:12 PM | P | NR |
|
|
Phone #: ###-#### called contr requested inspection by mistake job not ready
|
ELE06-04355
| Final | 2/1/2007 | 2/1/2007 | 2/1/2007 12:57:56 PM | P | PASS |
|
|
Phone #: ###-#### ok shell and core only card signed
|
ELE06-04586
| Final | 2/1/2007 | 2/1/2007 | 2/1/2007 12:57:16 PM | P | FAIL |
|
|
Phone #: ###-#### corrr. called 110.26(A)(1) table shall provide required clearences for panels, 406.4(A B D) recepts are loose in boxes and set back in plates, all locations
|
ELE07-00277
| Electrical Rough-In | 1/31/2007 | 2/1/2007 | 2/1/2007 11:09:15 AM | A | PASS |
|
|
jason - the painter will let you; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok added final ok
|
ELE07-00277
| Final | 2/1/2007 | 2/1/2007 | 2/1/2007 11:08:37 AM | A | PASS |
|
|
jason - the painter will let you; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok
|
ELE07-00103
| Final | 1/31/2007 | 2/1/2007 | 2/1/2007 10:55:21 AM | A | FAIL |
|
|
lewis; Phone #: ###-#### Internet Inspection Request from: Victoria Beall corr. fee due called 310.15(B)(2)(a) derate conductors from p/s to jbox (old panel)
|
ELE06-04035
| Final | 1/31/2007 | 2/1/2007 | 2/1/2007 10:27:33 AM | A | FAIL |
|
|
garage code 2690 Phone #: 208-371-641 corr. corr. called 314.16 box fill island counter
|
ELE06-02125
| Final | 1/31/2007 | 2/1/2007 | 2/1/2007 9:53:05 AM | A | FAIL |
|
|
Monument sign for Designs West Phone #: ###-#### corr. called 314.17 fitting required for all raceways that enter sign, 300.15 all splices shall be in box or enclosure, 314.23 support boxes if used, 300.12 mech continunity of raceways, 350.6, 352.6 shall use listed fttings for LFMC &RNC
|
ELE06-04523
| Final | 1/31/2007 | 2/1/2007 | 2/1/2007 9:20:44 AM | A | CANC |
|
|
This is the C & C cleaners on State. Phone #: ###-#### called need correct address should be 5622 w state
|
ELE06-04337
| Final | 1/31/2007 | 2/1/2007 | 2/1/2007 8:42:21 AM | A | PASS |
|
|
kelly; Phone #: ###-#### Internet Inspection Request from: Victoria ok flex fittings removed final ok
|