Inspections for the day of: Friday, February 1, 2008.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-00104 ELE-Aging Inspection2/1/20082/1/20082/4/2008 4:13:50 PM NR
Tom said he would check into this
ELE06-04678 ELE-Aging Inspection2/1/20082/1/20082/4/2008 12:02:21 PM PASS
ELE08-00240 Electrical Rough-In2/1/20082/1/20082/1/2008 4:25:09 PMPPASS
Please inspect outlets in bedroom and garage.Electrician is Tony Norton @ ###-####. Customer is Bob Bolinder @ ###-#### Phone #: ###-#### Internet Inspection Request from: gary batten
ELE08-00240 DOC - Permit Finaled2/1/20082/1/20082/1/2008 4:24:59 PMPPASS
ELE06-04442 ELE-Aging Inspection2/1/20082/1/20082/1/2008 3:38:29 PM NR
suc
ELE07-04092 Electrical Rough-In2/1/20082/1/20082/1/2008 3:21:08 PMPPART
Ceiling inspection please-Spencer Phone #: ###-####
another permit has to be taken out for 301 and inspections streightened out.
ELE08-00249 Electrical Rough-In2/1/20082/1/20082/1/2008 2:48:15 PMPPASS
chad Phone #: ###-####

R/I Ok
ELE08-00179 Final1/31/20082/1/20082/1/2008 2:41:13 PMPPASS
Scheduled by a contractor via Hello! on 1/31/2008 at 10:56:33 AM. Contact: ###-####.
ELE07-04055 Final1/31/20082/1/20082/1/2008 1:43:27 PMPPASS
TRENT Phone #: ###-####
ELE07-04054 Final1/31/20082/1/20082/1/2008 1:23:27 PMPPASS
TRENT Phone #: ###-####
ELE07-04053 Final1/31/20082/1/20082/1/2008 12:42:36 PMPPASS
TRENT Phone #: ###-####
ELE07-02064 Permanent Service1/31/20082/1/20082/1/2008 11:21:41 AMAPASS
jared Phone #: ###-####
check transformer grounding and bonding later 12 1/2 % rule and landing GEC on neutral also 1/2 in flex is only good for 20 a and should not be used to incase GEC
P/S U/G N Ok
ELE08-00077 Permanent Service1/31/20082/1/20082/1/2008 10:42:26 AMAPART
Inspect new service location within Eddie Bauer tenant improvement. Owner would like to be able to transfer power sometime Friday. Phone #: ###-#### Internet Inspection Request from: Tracy Robertson
Grounding electrode conductor andground to 200a panel to be #4 land GEC in neutral bus of transformer
ELE08-00168 Permanent Service1/31/20082/1/20082/1/2008 9:47:56 AMAPASS
final inspection on service and panel upgrades. Building owner will be there to let us in to all units @8:30 would like to have inspection at 9:00a:m if possible, any questions call Andy @ ###-#### or ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose
ELE08-00168 DOC - Permit Finaled2/1/20082/1/20082/1/2008 9:47:47 AMPPASS
ELE08-00152 Conference1/30/20082/1/20082/1/2008 9:24:40 AMAPART
erik Phone #: ###-#### -or ###-#### - please call 1/2 hr prior to inspection
talked about general requiements