ELE16-00026
| Final | 2/1/2016 | 2/1/2016 | 2/1/2016 1:56:33 PM | P | PASS |
|
|
Bill Phone #: ###-#### final ok
|
ELE16-00296
| Electrical Rough-In | 2/1/2016 | 2/1/2016 | 2/1/2016 1:15:03 PM | P | PASS |
|
|
inspect underground conduit. Phone #: ###-#### Inspection requested via web by Robert Schroder r/i u. ground conduit to garage and secondary ok
|
ELE16-00295
| Electrical Rough-In | 2/1/2016 | 2/1/2016 | 2/1/2016 1:14:03 PM | P | PASS |
|
|
inspect underground conduit Phone #: ###-#### Inspection requested via web by Robert Schroder r/i u. ground conduit to garage and secondary ok
|
ELE16-00294
| Electrical Rough-In | 2/1/2016 | 2/1/2016 | 2/1/2016 1:12:39 PM | P | PASS |
|
|
inspect underground conduit Phone #: ###-#### Inspection requested via web by Robert Schroder r/i u. ground and secondaries ok
|
ELE16-00106
| Final | 1/31/2016 | 2/1/2016 | 2/1/2016 12:09:59 PM | A | PASS |
|
|
Please call if there are any issues. I will be nearby Phone #: ###-#### Inspection requested via web by shane farwell correction made final ok
|
ELE16-00297
| Final | 2/1/2016 | 2/1/2016 | 2/1/2016 10:33:12 AM | A | FAIL |
|
|
service inspect for Idaho power, lock box at front door, 2525 Phone #: ###-#### Inspection requested via web by Charles Davis 250.53(A)(3)-Confirm grounding electrode and install supplemental since water pipe not accessable or can't find where enters structure. Asked Charles to get rid of nm cable feeding detached garage
|
ELE15-02995
| Final | 1/29/2016 | 2/1/2016 | 2/1/2016 10:03:54 AM | A | FAIL |
|
|
The key is in a lock box mounted to the fence, the code is 1225, Any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren called to leave message for both 907 and 909, mailbox full. No power to half of kitchen counter and no power to outside receptacles, identify garage disconnect switch 225.37
|
ELE15-02994
| Final | 1/29/2016 | 2/1/2016 | 2/1/2016 9:55:55 AM | A | FAIL |
|
|
The key is in a lock box mounted to the fence, the code is 1225, Any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren intersytem bon buss hanging in midair, identify garage disconnect switch, upst. bathroom ceiling fixture not rated for wet location halfway in tub enclosure.
|
ELE15-02878
| Electrical Rough-In | 1/29/2016 | 2/1/2016 | 2/1/2016 9:00:16 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Daniel Schaffeld r/i ok Buster said they will add outside receptacle within 25 foot of C/U and to have receptacle at front of house to meet code. Wall spaces inside not meeting receptacle spacing will have radiators in those spaces
|