ELE15-04124
| Final | 2/10/2016 | 2/10/2016 | 2/10/2016 3:20:23 PM | P | PASS |
|
|
please call prior to arrival for access. Phone #: ###-#### Inspection requested via web by Patrick Paz final ok
|
ELE16-00185
| Electrical Rough-In | 2/9/2016 | 2/10/2016 | 2/10/2016 2:23:27 PM | P | PASS |
|
|
Ben-underground Phone #: ###-#### r/i underslab in office areas ok to cover
|
ELE15-04091
| Final | 2/9/2016 | 2/10/2016 | 2/10/2016 1:38:54 PM | P | PASS |
|
|
If you have any questions, please call Calvin ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan final ok
|
ELE15-03149
| Final | 2/10/2016 | 2/10/2016 | 2/10/2016 1:10:56 PM | P | PASS |
|
|
final out this permit for Powerbound. Sublime electric finishing trimout with permit # ele15-04091
|
ELE16-00382
| Permanent Service | 2/10/2016 | 2/10/2016 | 2/10/2016 12:52:33 PM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by David McClellan need available fault current info and label 110.24 (A)
|
ELE15-03849
| Electrical Rough-In | 2/10/2016 | 2/10/2016 | 2/10/2016 12:24:10 PM | P | PASS |
|
|
Cover for the walls Phone #: ###-#### Inspection requested via web by Stan Woodward r/i all walls and bath ceilings ok
|
ELE16-00285
| Final | 2/10/2016 | 2/10/2016 | 2/10/2016 12:02:32 PM | A | PASS |
|
|
please call 3 minutes prior to arrival. Would like mid morning,,1:3 or there abouts. Phone #: ###-#### Inspection requested via web by John Edwards corrections made final ok
|
ELE15-04010
| Electrical Rough-In | 2/9/2016 | 2/10/2016 | 2/10/2016 10:22:53 AM | A | DEFR |
|
|
Rocky Phone #: ###-#### r/i ok walls and hardlid ceilings reception and apt. areas (conduit installed instead of wiremold down walls as per Bob R.) ** Inspection transfered to ELE15-03491 - 2525 Sunrise Rim Rd - inspection was called in under wrong ELE permit and was corrected 3/22/16 by C_P
|
ELE15-04089
| Electrical Rough-In | 2/9/2016 | 2/10/2016 | 2/10/2016 10:09:14 AM | P | PASS |
|
|
Underground inspection. Contact Craig Timmons. Phone #: ###-#### Inspection requested via web by Cathy Duchek r/i u. slab raceways from grid line 3 to 5 ok
|
ELE12-02755
| Final | 2/9/2016 | 2/10/2016 | 2/10/2016 9:29:54 AM | P | FAIL |
|
|
Barbara// please call before Phone #: ###-#### As per manufacturers label on door, maximum breaker in top space 50 amps. Relocate 100 amp breaker to other position and blank off top spaces
|
GCE15-00173
| GCE-Final | 2/9/2016 | 2/10/2016 | 2/10/2016 8:45:10 AM | A | PASS |
|
|
Greg ###-#### code: 3522 final ok
|
GCE15-00172
| GCE-Final | 2/9/2016 | 2/10/2016 | 2/10/2016 8:44:29 AM | A | PASS |
|
|
Greg ###-#### code: 3522 final ok
|
ELE15-03491
| Electrical Rough-In | 2/9/2016 | 2/10/2016 | 2/10/2016 12:00:00 AM | A | PASS |
|
|
Rocky Phone #: ###-#### r/i ok walls and hardlid ceilings reception and apt. areas (conduit installed instead of wiremold down walls as per Bob R.) ** applicant called in inspection for wrong ELE15-04010 permit. Inspection transfer to proper ELE to show accurate inspection records
|