Inspections for the day of: Thursday, February 11, 2016.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC15-01287 Conference2/9/20162/11/20162/12/2016 3:59:29 PMAFAIL
Wattles and entrance installed on site as requested. Some clean of site has occurred.

Cement sludge and dirt from site in gutter that has towards the storm drain. Cement truck dripped oil. Mud smells like oil.

Clean up is needed ASAP with re-inspection required Tuesday.
ESC15-00177 General Inspection2/11/20162/11/20162/12/2016 3:21:50 PM PASS
Silt fence installed and to be removed late Spring
ESC15-00586 General Inspection2/11/20162/11/20162/12/2016 3:20:31 PM NR
No activity has occured on parcel. Permits issued in November. No issues
ESC15-01513 General Inspection2/10/20162/11/20162/12/2016 2:26:31 PMACANC
rescheduled
ESC15-00706 Aging Inspection2/11/20162/11/20162/11/2016 4:04:08 PM PASS
Home complete, landscaped and occupied. ESC conditions satisfied. No loose material or temp BMPs remaining.
ESC15-00706 DOC - Permit Finaled2/11/20162/11/20162/11/2016 4:04:00 PMPPASS
ESC15-00707 Aging Inspection2/11/20162/11/20162/11/2016 4:03:53 PM PASS
Home complete, landscaped and occupied. ESC conditions satisfied. No loose material or temp BMPs remaining.
ESC15-00707 DOC - Permit Finaled2/11/20162/11/20162/11/2016 4:03:06 PMPPASS
ESC14-01063 Conference2/10/20162/11/20162/11/2016 3:26:38 PMPDONE
2 PM Developer to explain new ESC plan for EC phases. Site walk through requested.

Plan is to allow dewatering off lots in EC #8 to allow for them to dry and be re-worked. Water will discharge into the new EC#8 pond. This pond is to be cleaned out and re-approved by ACHD (bond issued) so any sediment in the water will be caputured in the permanent stormwater facilities and then cleaned.

Once dewatered, perimeter BMPs will be installed correctly. Other corrections and actions are pending.
ESC14-00941 General Inspection2/11/20162/11/20162/11/2016 1:03:15 PM PASS
ESC14-00809 General Inspection2/11/20162/11/20162/11/2016 11:34:49 AM PASS
ESC15-01072 Aging Inspection2/11/20162/11/20162/11/2016 10:40:51 AM PASS
Earth Energy work complete and no longer on site., Area still in use for bridge related activities. Will continue to monitor.
ESC15-00468 BMP Violation2/11/20162/11/20162/11/2016 10:39:35 AMPCANC
data entry error. disregard
ESC15-00468 BMP Violation2/10/20162/11/20162/11/2016 10:38:56 AMPPEND
To Ensure BMP's violation from Posted Correction Notice have been addressed and fixed per BCC 8-17. Came in as a Complaint

Compliance time extended by 24 hr per Evan
ESC14-00664 General Inspection2/11/20162/11/20162/11/2016 10:27:45 AM PASS
Construction now covered under ESC15-00731. This phase is complete. No need for duplicate site inspections. Permit finaled. No violations.
ESC14-00664 DOC - Permit Finaled2/11/20162/11/20162/11/2016 10:26:45 AMPPASS
ESC11-00192 General Inspection2/11/20162/11/20162/11/2016 9:47:58 AM PASS
ESC13-00193 General Inspection2/11/20162/11/20162/11/2016 8:42:13 AM PASS
WIP on first SFH by Jayo Construction. Both homebuilder and developer will maintain BMPs per Shane. Perimeter BMPs, DI bags, and slope stabilization are currently in good shape. Will need stockpile protection if it is not backfilled - Shane stated it will not stay on that upper lot on Sand Dune on the slope.

No corrections issued at this time. Will continue to monitor since this is first construction on this phase in over 1 year.