Inspections
/
Inspector Activity
Inspections for the day of:
Wednesday, February 12, 2014
.
Number of inspections:
9
Percentage of inspections complete:
100 %
Percentage of inspections not complete:
0 %
Contact Information
Inspector
Andy J. Long
Title
EROSION INSPECTOR
Phone #
794-8996
Permit Number
Description
Received
Requested
Completed
AM/PM
Disposition
ESC13-00930
General Inspection
2/12/2014
2/12/2014
2/13/2014 11:16:20 AM
PASS
ESC13-00715
General Inspection
2/12/2014
2/12/2014
2/13/2014 10:49:28 AM
PASS
Slab for generator has been poured. No trackout or stockpiling onsite. Approved.
ESC13-00069
General Inspection
2/12/2014
2/12/2014
2/13/2014 10:23:09 AM
PASS
Construction entrance has been replenished and roundabout cleaned per the C/N issued Monday 2/10. No new violations observed. Approved.
ESC13-00473
Aging Inspection
2/12/2014
2/12/2014
2/13/2014 9:24:40 AM
PASS
Finished but not yet stabilized. Has the wrong address per PDS map, say 2522 instead of 2552. No ESC violations.
ESC13-01138
General Inspection
2/12/2014
2/12/2014
2/13/2014 8:59:49 AM
PASS
ESC13-00997
General Inspection
2/12/2014
2/12/2014
2/13/2014 8:34:48 AM
PASS
ESC13-00524
Conference
2/12/2014
2/12/2014
2/12/2014 12:21:15 PM
P
DONE
Co nference called due to need for correctiions and maintenance of BMPs. Snowmelt, rainfall, and the ground thawing has created multiple ESC issues.
RP Bob Berryman of Central Paving and Doug Powell, the site engineer met me onsite to discuss corrections.
1. Channel erosion below final check dam will have banks regraded and length of riprap extended. Working with PW engineers Jim Wylie on these corrections.
2. Blowouts onto roads will be cleaned.
3. Additional check dams to be installed at lower intersection problem area.
4. Drainage protection to be enhanced on upper drain on main subdivision road.
Central Paving started on corrections at end of conference. Dave Powell will be onsite daily this week to supervise.
Hydroseeding/mulching on remaining areas is scheduled for next week.
Will check back 2/13 to monitor progress.
ESC13-01174
General Inspection
2/12/2014
2/12/2014
2/12/2014 8:57:10 AM
PASS
ESC13-00701
General Inspection
2/12/2014
2/12/2014
2/12/2014 8:47:18 AM
PASS