Inspections for the day of: Thursday, February 12, 2015.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-00388 Electrical Rough-In2/12/20152/12/20152/12/2015 2:43:27 PMPPASS
Phone #: ###-#### Inspection requested via web by Eric Schroeder Master bath only at this time rough in ok cover
ELE15-00154 Electrical Rough-In2/11/20152/12/20152/12/2015 2:23:10 PMPPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Grid north side rough in ok cover
ELE15-00387 Permanent Service2/12/20152/12/20152/12/2015 2:03:54 PMPPASS
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack p/s u/g n ok
ELE14-02796 Final2/12/20152/12/20152/12/2015 1:39:06 PMPPASS
Phone #: ###-#### Inspection requested via web by Thomas Jenkins Available fault current under 22k. will be posted when sign complete. Final ok
ELE15-00383 Electrical Rough-In2/11/20152/12/20152/12/2015 1:25:49 PMPPASS
Please inspect the kitchen for cover Phone #: ###-#### Inspection requested via web by Spencer McLean Kicchen only at this time rough in ok cover
ELE15-00203 Final2/11/20152/12/20152/12/2015 1:03:02 PMPPASS
Danny is the on site contact. Phone #: ###-#### Inspection requested via web by Buster Bowen Grounded conductor bond completed in transformers. Final ok
ELE15-00363 Permanent Service2/11/20152/12/20152/12/2015 12:09:14 PMAPASS
Late morning if possible. Phone #: ###-#### Inspection requested via web by Brad Girard p/s o/h rec ok
ELE15-00369 Final2/11/20152/12/20152/12/2015 10:39:34 AMAFAIL
Please call Shannon 30 min prior at ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates Furnace located in crawl, access in back yard. Verbal with wireman.
210.63- Heating, Refrigeration Equipment Outlet. A 125-volt, single-phase, 15- or
20-ampere-rated receptacle outlet shall be installed at an accessible location for the servicing of heating, airconditioning, and refrigeration equipment. The receptacle shall be located on the same level and within 7.5 m (25 ft) of the heating, air-conditioning, and refrigeration equipment. The receptacle outlet shall not be connected to the load side of the equipment disconnecting means.
210.70 Lighting Outlets Required. Lighting outlets shall be installed where specified in 210.70(A), (B), and (C). (3) Storage or Equipment Spaces. For attics, underfloor spaces, utility rooms, and basements, at least one lighting outlet containing a switch or controlled by a wall switch shall be installed where these spaces are used for storage or contain equipment requiring servicing. At least one point of control shall be at the usual point of entry to these spaces. The lighting outlet shall be provided at or near the equipment requiring servicing.
ELE15-00384 Final2/11/20152/12/20152/12/2015 9:51:52 AMAPASS
Gate on left side of Home... Owner should be home, Phone #: ###-#### Inspection requested via web by JOHN MCCURDY Final ok
ELE14-01914 Final2/11/20152/12/20152/12/2015 9:12:47 AMAPASS
Garage code 6314 Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
ELE14-01588 Final2/11/20152/12/20152/12/2015 9:11:13 AMAPASS
Garage code 6314 Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
ELE15-00371 Permanent Service2/11/20152/12/20152/11/2015 3:15:04 PMAPASS
This permit was pulled with the assistance of Darryl Degrange solely for the inspection of an existing meter that has been de-energized for more than 1 year and needs to be energized thus requiring an inspection. The meter provides power to a breaker marked "house" and provides power only for the exterior lighting on the building. Please call Dave upon completion of the inspection so we can relay to Idaho Power. Please also final if no defects are noted. Phone #: ###-#### Inspection requested via web by David Mackey House panel meter p/s u/g rec ok
MIS15-00032 ELE-Conference2/11/20152/12/20152/11/2015 2:43:48 PMAFAIL
Boise City Ordinance 4-05-18 Before any person installs or alters any electrical wiring, equiptment, apparatus, or fixture, they shall file a permit application with the electrical section.
Permit required for wiring in garage for outlets.