ELE15-00388
| Electrical Rough-In | 2/12/2015 | 2/12/2015 | 2/12/2015 2:43:27 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Eric Schroeder Master bath only at this time rough in ok cover
|
ELE15-00154
| Electrical Rough-In | 2/11/2015 | 2/12/2015 | 2/12/2015 2:23:10 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Grid north side rough in ok cover
|
ELE15-00387
| Permanent Service | 2/12/2015 | 2/12/2015 | 2/12/2015 2:03:54 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack p/s u/g n ok
|
ELE14-02796
| Final | 2/12/2015 | 2/12/2015 | 2/12/2015 1:39:06 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Thomas Jenkins Available fault current under 22k. will be posted when sign complete. Final ok
|
ELE15-00383
| Electrical Rough-In | 2/11/2015 | 2/12/2015 | 2/12/2015 1:25:49 PM | P | PASS |
|
|
Please inspect the kitchen for cover Phone #: ###-#### Inspection requested via web by Spencer McLean Kicchen only at this time rough in ok cover
|
ELE15-00203
| Final | 2/11/2015 | 2/12/2015 | 2/12/2015 1:03:02 PM | P | PASS |
|
|
Danny is the on site contact. Phone #: ###-#### Inspection requested via web by Buster Bowen Grounded conductor bond completed in transformers. Final ok
|
ELE15-00363
| Permanent Service | 2/11/2015 | 2/12/2015 | 2/12/2015 12:09:14 PM | A | PASS |
|
|
Late morning if possible. Phone #: ###-#### Inspection requested via web by Brad Girard p/s o/h rec ok
|
ELE15-00369
| Final | 2/11/2015 | 2/12/2015 | 2/12/2015 10:39:34 AM | A | FAIL |
|
|
Please call Shannon 30 min prior at ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates Furnace located in crawl, access in back yard. Verbal with wireman. 210.63- Heating, Refrigeration Equipment Outlet. A 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be installed at an accessible location for the servicing of heating, airconditioning, and refrigeration equipment. The receptacle shall be located on the same level and within 7.5 m (25 ft) of the heating, air-conditioning, and refrigeration equipment. The receptacle outlet shall not be connected to the load side of the equipment disconnecting means. 210.70 Lighting Outlets Required. Lighting outlets shall be installed where specified in 210.70(A), (B), and (C). (3) Storage or Equipment Spaces. For attics, underfloor spaces, utility rooms, and basements, at least one lighting outlet containing a switch or controlled by a wall switch shall be installed where these spaces are used for storage or contain equipment requiring servicing. At least one point of control shall be at the usual point of entry to these spaces. The lighting outlet shall be provided at or near the equipment requiring servicing.
|
ELE15-00384
| Final | 2/11/2015 | 2/12/2015 | 2/12/2015 9:51:52 AM | A | PASS |
|
|
Gate on left side of Home... Owner should be home, Phone #: ###-#### Inspection requested via web by JOHN MCCURDY Final ok
|
ELE14-01914
| Final | 2/11/2015 | 2/12/2015 | 2/12/2015 9:12:47 AM | A | PASS |
|
|
Garage code 6314 Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
|
ELE14-01588
| Final | 2/11/2015 | 2/12/2015 | 2/12/2015 9:11:13 AM | A | PASS |
|
|
Garage code 6314 Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
|
ELE15-00371
| Permanent Service | 2/11/2015 | 2/12/2015 | 2/11/2015 3:15:04 PM | A | PASS |
|
|
This permit was pulled with the assistance of Darryl Degrange solely for the inspection of an existing meter that has been de-energized for more than 1 year and needs to be energized thus requiring an inspection. The meter provides power to a breaker marked "house" and provides power only for the exterior lighting on the building. Please call Dave upon completion of the inspection so we can relay to Idaho Power. Please also final if no defects are noted. Phone #: ###-#### Inspection requested via web by David Mackey House panel meter p/s u/g rec ok
|
MIS15-00032
| ELE-Conference | 2/11/2015 | 2/12/2015 | 2/11/2015 2:43:48 PM | A | FAIL |
|
|
Boise City Ordinance 4-05-18 Before any person installs or alters any electrical wiring, equiptment, apparatus, or fixture, they shall file a permit application with the electrical section. Permit required for wiring in garage for outlets.
|