MEC18-00525
| Rough-in | 2/12/2018 | 2/12/2018 | 2/12/2018 4:17:59 PM | P | FAIL |
|
|
please add FP inspection also.. Thank you!! Phone #: ###-#### Inspection requested via web by dannyel chaloupka- need all framing completed around duct work- fresh air to RA plenum needs sealed and insulated in attic the rest by final- flue guage at zero- bare copper on lineset ion joist space needs armaflex fixed along with other rips and tears- b vent has no slope from roof to garage ceiling running up hill and supports need tightened- insulation shield needs 1" clearance to b vent and secured- left correction notice front window- Fireplace R/I ok- rest of R/I ok
|
MEC18-00525
| Pressure Test | 2/12/2018 | 2/12/2018 | 2/12/2018 4:07:09 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- 20lb gas pass
|
MEC17-05135
| Rough-in | 2/12/2018 | 2/12/2018 | 2/12/2018 3:21:16 PM | P | PASS |
|
|
Cover inspection - call mark Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok- ok for ceiling tiles
|
MEC18-00653
| Final | 2/12/2018 | 2/12/2018 | 2/12/2018 2:51:37 PM | P | PASS |
|
|
Please call when you are on your way so we can let you in the crawl space.Thanks! Phone #: ###-#### Inspection requested via web by Dan McFate- electric furnace in crawl CO ok
|
MEC18-00635
| Final | 2/9/2018 | 2/12/2018 | 2/12/2018 2:27:04 PM | P | PASS |
|
|
INSTALLER AL ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- unit heater ok in garage
|
MEC18-00635
| Pressure Test | 2/12/2018 | 2/12/2018 | 2/12/2018 2:26:39 PM | P | PASS |
|
|
INSTALLER AL ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass from meter location to unit heater
|
MEC18-00629
| Final | 2/12/2018 | 2/12/2018 | 2/12/2018 1:46:25 PM | P | PASS |
|
|
mini split ok
|
MEC18-00517
| Rough-in | 2/12/2018 | 2/12/2018 | 2/12/2018 1:40:02 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- fresh air to RA plenum can not come from roof- need ladder provided to access furn and coil in attic- left notice front window
|
MEC18-00517
| Pressure Test | 2/12/2018 | 2/12/2018 | 2/12/2018 1:39:01 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- 20lb gas pass
|
MEC17-05750
| Final | 2/12/2018 | 2/12/2018 | 2/12/2018 1:06:50 PM | P | PASS |
|
|
correction made
|
MEC18-00070
| Final | 2/9/2018 | 2/12/2018 | 2/12/2018 10:51:49 AM | A | FAIL |
|
|
Please call owner John when in route to home ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd- need to witness flue pressure test
|
MEC18-00067
| Final | 2/9/2018 | 2/12/2018 | 2/12/2018 10:01:59 AM | A | PASS |
|
|
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- TI final ok- card signed
|
MEC18-00066
| Final | 2/12/2018 | 2/12/2018 | 2/12/2018 10:01:03 AM | A | PASS |
|
|
shell and core final ok
|
MEC18-00525
| Rough-in | 2/12/2018 | 2/12/2018 | 2/12/2018 9:00:45 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka
|
MEC16-04538
| Mec-Aging Inspection | 2/12/2018 | 2/12/2018 | 2/12/2018 8:54:01 AM | | PEND |
|
|
contractor will schedule final per phone call
|
MEC16-04507
| Mec-Aging Inspection | 2/12/2018 | 2/12/2018 | 2/12/2018 8:49:44 AM | | PEND |
|
|
contractor will schedule for final per phone call
|
MEC17-02534
| Mec-Aging Inspection | 2/12/2018 | 2/12/2018 | 2/12/2018 8:46:38 AM | | FAIL |
|
|
needs to be called in for final- last final was a partial- will need air balance report onsite
|
MEC16-04470
| Mec-Aging Inspection | 2/12/2018 | 2/12/2018 | 2/12/2018 8:44:30 AM | | PEND |
|
|
contractor looking into this
|
MEC17-05300
| Final | 2/9/2018 | 2/12/2018 | 2/12/2018 8:41:23 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- need to support both condensate lines off furnace and coil- did you install fireplace ?
|
MEC18-00525
| Pressure Test | 2/12/2018 | 2/12/2018 | 2/12/2018 7:03:27 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka
|
MEC18-00525
| Rough-in | 2/12/2018 | 2/12/2018 | 2/12/2018 7:03:19 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka
|
MEC17-04935
| Pressure Test | 2/9/2018 | 2/12/2018 | 2/9/2018 1:38:12 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Devony Bullard Inspection cancelled from web by: Devony Bullard
|
MEC17-05175
| Pressure Test | 2/9/2018 | 2/12/2018 | 2/9/2018 1:37:39 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Devony Bullard Inspection cancelled from web by: Devony Bullard
|
MEC17-05258
| Pressure Test | 2/9/2018 | 2/12/2018 | 2/9/2018 1:37:02 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Devony Bullard Inspection cancelled from web by: Devony Bullard
|
MEC17-05258
| Pressure Test | 2/9/2018 | 2/12/2018 | 2/9/2018 11:12:57 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Devony Bullard Inspection cancelled from web by: Devony Bullard
|
MEC18-00482
| Final | 2/6/2018 | 2/12/2018 | 2/8/2018 2:31:14 PM | A | CANC |
|
|
Please have inspector call tech when in route to home for final flue pressure test and final. Tech is Aaron at ###-#### Phone #: ###-#### >> Inspection requested via web by Carolyn Rudd Inspection cancelled from web by: Carolyn Rudd
|