BLD19-02407
| BLD-Footing | 2/12/2020 | 2/12/2020 | 2/12/2020 3:56:37 PM | P | NR |
|
|
Sergio Phone #: ###-####//frost is still present//
|
BLD20-00137
| BLD-Footing | 2/12/2020 | 2/12/2020 | 2/12/2020 3:44:52 PM | P | NR |
|
|
Sergio Phone #: ###-####//still has frozen ground//
|
BLD19-02667
| BLD-Footing | 2/12/2020 | 2/12/2020 | 2/12/2020 3:44:16 PM | P | NR |
|
|
Sergio Phone #: ###-####//still has frozen ground//
|
BLD19-04669
| BLD-Footing | 2/11/2020 | 2/12/2020 | 2/12/2020 3:41:45 PM | P | PART |
|
|
Pat Phone #: ###-####//Wip//bar installed//string set for easment, building appears to be outside of easment line based on strings set by contractor//no frost observed onsite at time of isnpection//blankets onsite//
|
BLD19-00843
| BLD-Final | 2/11/2020 | 2/12/2020 | 2/12/2020 3:26:36 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Zach Carter
|
BLD19-02398
| BLD-Wall Bracing | 2/11/2020 | 2/12/2020 | 2/12/2020 1:47:24 PM | P | PART |
|
|
RE-INSPECTION for completed Items including noted strapping at windows per details on plans ; noted truss blocking per truss details and plans at strapping required on roof decking. Phone #: ###-#### Inspection requested via web by Wes Harrison//truss blocking installed//strapping installed and nailed per plans// exterior nailing and shear ok//
|
BLD19-00239
| BLD-Final | 2/11/2020 | 2/12/2020 | 2/12/2020 12:56:39 PM | P | PASS |
|
|
Drew Phone #: ###-####//final complete smoke and co detectors installed//garage separation wall taped//
|
BLD19-00239
| DOC - Permit Finaled | 2/12/2020 | 2/12/2020 | 2/12/2020 12:56:23 PM | P | PASS |
|
|
|
BLD19-03493
| BLD-Final | 2/11/2020 | 2/12/2020 | 2/12/2020 12:37:15 PM | P | NR |
|
|
Marcus Phone #: ###-####///needs fire life safety final complete prior to final building inspection//
|
BLD19-04743
| BLD-Footing | 2/11/2020 | 2/12/2020 | 2/12/2020 11:55:04 AM | P | FAIL |
|
|
Brian Phone #: ###-####//1/2 of footings subgrade frozen//
|
BLD19-04306
| BLD-Final | 2/11/2020 | 2/12/2020 | 2/12/2020 11:39:45 AM | A | NR |
|
|
Dean Phone #: ###-####
|
MIS20-00045
| BLD-Conference | 2/12/2020 | 2/12/2020 | 2/12/2020 10:43:23 AM | P | CANC |
|
|
follow up on CN....
|
MIS20-00045
| BLD-Conference | 2/12/2020 | 2/12/2020 | 2/12/2020 10:41:40 AM | P | DONE |
|
|
Per Brian Mechanical Inspector, no permit for framing on outside flue Phone #: ###-####//CN left with owner//need permit for chase for mechanical vent, will need to expose framing for inspection building and mechanical//also noted that permit for interior remodel will be needed if more than cosmetic//appears to be mechanical, electrical and plumbinng permits for interior remodel//follow up 10 days//
|
BLD19-04031
| BLD-Energy code compliance | 2/11/2020 | 2/12/2020 | 2/12/2020 10:33:45 AM | A | PASS |
|
|
Jeff Phone #: ###-####
|
BLD19-04725
| BLD-Wall Bracing | 2/11/2020 | 2/12/2020 | 2/12/2020 10:29:29 AM | A | PART |
|
|
Brian Phone #: ###-####//interior shear wall only//will need to see verification that hold downs were installed//
|
BLD19-03656
| BLD-Wall Bracing | 2/11/2020 | 2/12/2020 | 2/12/2020 9:27:01 AM | A | FAIL |
|
|
Vince Phone #: ###-####//still need to install straping//portal frame still needed//CN still stands until all corrections made//site contact was informed to complete all corrections and call for re-inspection when complete//
|
BLD19-04033
| BLD-Framing/Rough-in | 2/11/2020 | 2/12/2020 | 2/12/2020 9:09:08 AM | A | PASS |
|
|
Jeff Phone #: ###-####//most corrections made//still need to add nails to truss scabs per engineering//ok to insulate//
|
BLD18-01778
| BLD-Aging Inspection | 2/12/2020 | 2/12/2020 | 2/12/2020 8:21:53 AM | | DONE |
|
|
Expires: 03/29/20
|
BLD18-01768
| BLD-Aging Inspection | 2/12/2020 | 2/12/2020 | 2/12/2020 8:21:05 AM | | CANC |
|
|
|