PLM02-00310
| Plumbing Rough-in | 2/12/2002 | 2/13/2002 | 2/13/2002 12:00:00 AM | A | PART |
|
|
###-#### up date water distribution to new bathroom,s . relocate expansion tank to cold water side of water heater. repipe T&P line. provide approved type hose bibb,s to out side of building . repipe kit sink vent through roof. have D.C. tested and certified . it,s ok to cover floor and wall,s only for new bathroom,s 2/13/2002 3:09:02 PM
|
PLM02-00342
| Plumbing Rough-in | 2/12/2002 | 2/13/2002 | 2/13/2002 12:00:00 AM | A | PASS |
|
|
###-#### dennis
|
PLM01-03723
| Final | 2/12/2002 | 2/13/2002 | 2/13/2002 12:00:00 AM | A | PART |
|
|
DAREN VOICE PAGER ###-#### have R.P. for soap dispenser tested and certified. finish labling med gas zone valves 2/13/2002 12:35:02 PM
|
PLM02-00344
| Plumbing Rough-in | 2/12/2002 | 2/13/2002 | 2/13/2002 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 02/12/2002 at 15:43:35. Contact: ###-####.
|
PLM02-00292
| Roof Drains | 2/13/2002 | 2/13/2002 | 2/13/2002 12:00:00 AM | A | PART |
|
|
###-#### north and east section of roof drain line to pit,s water test ok 2/13/2002 5:56:24 PM
|
PLM02-00311
| Plumbing Rough-in | 2/13/2002 | 2/13/2002 | 2/13/2002 12:00:00 AM | P | NR |
|
|
mary ###-#### r/i
|
PLM02-00304
| Plumbing Rough-in | 2/13/2002 | 2/13/2002 | 2/13/2002 12:00:00 AM | P | PART |
|
|
Scheduled by a contractor via Hello! on 02/13/2002 at 07:46:48. Contact: ###-####. groundwork in restroom,s and for new mop sink test ok. ok to cover 2/13/2002 3:39:52 PM
|