Inspections for the day of: Tuesday, February 13, 2007.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS07-00019 BLD-Final2/9/20072/13/20072/13/2007 4:15:25 PMPPASS
Sefika ###-####. Temp. occ granted. Will be ok for perm occ once fire finals
BLD06-03276 BLD-Framing/Rough-in2/12/20072/13/20072/13/2007 3:29:53 PMPFAIL
ben; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Provide header over doorway upstairs @ k1 truss. Provide approved repair for k3A truss were holes were drillled for plumbing. Winder treads for stairway to cellar are non conforming. Needs to have 6 inch min at any point and not vary more than 3/8 inch at 12 inch alk line. c/n posted. ok to insul.
BLD06-03109 BLD-Framing/Rough-in2/12/20072/13/20072/13/2007 2:12:38 PMPNR
Scheduled by a contractor via Hello! on 2/12/2007 at 5:16:56 PM. Contact: ###-####. Needs other trades.
BLD06-00945 BLD-Footing2/13/20072/13/20072/13/2007 1:50:33 PMPPART
matt; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
BLD06-00910 BLD-Foundation2/13/20072/13/20072/13/2007 1:50:08 PMPPASS
matt; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
BLD06-00943 BLD-Foundation2/13/20072/13/20072/13/2007 1:49:39 PMPPASS
matt; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
BLD06-00944 BLD-Foundation2/13/20072/13/20072/13/2007 1:34:22 PMPPASS
matt; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
BLD06-03472 BLD-Footing2/12/20072/13/20072/13/2007 10:48:25 AMAPART
Will be ready for inspection at 11 a.m., pouring at noon. Please call Ben with questions. Phone #: ###-####
BLD06-03474 BLD-Footing2/12/20072/13/20072/13/2007 10:34:57 AMAPART
Pour time is noon. Ready for inspection at 11 a.m. If questions, call Ben. Phone #: ###-####
BLD06-03006 BLD-Final2/12/20072/13/20072/13/2007 9:55:07 AMAFAIL
greg; Phone #: ###-#### Internet Inspection Request from: Victoria Beall. Racks not anchored to conc. floor as per engineering. Contractor to contact engineer for possible change or complete work as per supplied engineering.
BLD06-02881 BLD-Conference2/12/20072/13/20072/13/2007 9:29:47 AMADONE
dwayne; Phone #: ###-#### Internet Inspection Request from: Victoria Beall. Wants to complete bonus room first. Noted to contractor to complete ri and ri insp at bonus room and then a partial framing insp. could be conducted.
BLD07-00299 BLD-Foundation2/12/20072/13/20072/13/2007 9:00:05 AMAPART
Scheduled by a contractor via Hello! on 2/12/2007 at 6:15:46 PM. Contact: ###-####.
BLD03-02388 BLD-Framing/Rough-in2/12/20072/13/20072/13/2007 12:00:00 AMACANC
mike; Phone #: ###-#### Internet Inspection Request from: Victoria Beall