ELE06-03440
| ELE-Aging Inspection | 2/13/2008 | 2/13/2008 | 2/19/2008 4:29:10 PM | | DONE |
|
|
looked for address, could not find
|
ELE05-00658
| Final | 2/13/2008 | 2/13/2008 | 2/13/2008 4:19:07 PM | P | PASS |
|
|
ok to final
|
ELE05-00517
| Final | 2/13/2008 | 2/13/2008 | 2/13/2008 3:45:08 PM | P | PASS |
|
|
ok to final
|
ELE07-03461
| Final | 2/12/2008 | 2/13/2008 | 2/13/2008 3:20:13 PM | P | NR |
|
|
Internet Inspection Request from: Randy Vail called contractor, needs panel cover installed, j-box covers installed, label all breakers, 1/14" by subpanel, backfill excavations at garage and house, fee due
|
ELE08-00276
| Electrical Rough-In | 2/12/2008 | 2/13/2008 | 2/13/2008 2:34:33 PM | P | PASS |
|
|
isidro Phone #: ###-#### ric ok, corrections made
|
ELE07-03457
| Electrical Rough-In | 2/13/2008 | 2/13/2008 | 2/13/2008 2:01:03 PM | P | PASS |
|
|
joe - cover for underground Phone #: ###-#### ok to cover u/g for trash compactor relocation
|
ELE06-00408
| Rough-In Permanent Service | 2/13/2008 | 2/13/2008 | 2/13/2008 12:55:22 PM | P | CANC |
|
|
call 1st before insp -james Phone #: ###-#### see conference
|
ELE06-00408
| Conference | 2/13/2008 | 2/13/2008 | 2/13/2008 12:55:07 PM | P | DONE |
|
|
call 1st before insp -james Phone #: ###-#### met owner, talked about concrete encased electrode, service disconnect, 6" free conductor length, ri work, height for breaker handles
|
ELE08-00276
| Permanent Service | 2/13/2008 | 2/13/2008 | 2/13/2008 12:15:10 PM | P | PASS |
|
|
p/s o/h n ok
|
ELE08-00257
| Electrical Rough-In | 2/12/2008 | 2/13/2008 | 2/13/2008 10:40:10 AM | A | PART |
|
|
calvin - trench Phone #: ###-#### ok to pour concrete encased electrode
|
ELE08-00339
| Rough-In Permanent Service | 2/12/2008 | 2/13/2008 | 2/13/2008 10:09:28 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson corrections made, ric ok, p/s u/g n ok
|
ELE04-00180
| Electrical Rough-In | 2/12/2008 | 2/13/2008 | 2/13/2008 9:53:20 AM | A | PASS |
|
|
john Phone #: ###-#### corrections made, ok to cover walls only, will have contractor do service later
|
ELE08-00331
| Temporary Service | 2/12/2008 | 2/13/2008 | 2/13/2008 9:32:44 AM | A | PASS |
|
|
alan Phone #: ###-#### corrections made, t/s o/h n ok
|
ELE07-04042
| Electrical Rough-In | 2/12/2008 | 2/13/2008 | 2/13/2008 9:06:24 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 2/12/2008 at 3:17:22 PM. Contact: ###-####. called, left correction notice, NEC 300.4(A) & (D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 314.20 boxes shall be flush or project therefrom in walls of combustible material, 210.70(A)(2) shall provide switched lighting outlet at garage entrance
|
ELE07-04041
| Electrical Rough-In | 2/12/2008 | 2/13/2008 | 2/13/2008 8:33:26 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 2/12/2008 at 3:18:49 PM. Contact: ###-####. called, left correction notice, NEC 314.16 box fill shall not be exceeded (kitchen), 334.30 shall not staple flat nm cable on edge, 300.4(A) & (D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 314.20 boxes shall be flush with or project therefrom in walls of combustible material, 210.70(A)(2) shall provide switched lighting outlet at garage entrance
|