ESC11-00879
| BMP Violation | 2/13/2014 | 2/13/2014 | 2/13/2014 2:41:00 PM | P | PASS |
|
|
follow up/hillside inspection.
Corrections made:
1. DI bags installed on MS4 on Boise Hills 2. Silt fences retrenched at base of hill 3. Additional wattles installed along Boise Hills. 4. Rills will be repaired as conditions allow, still very muddy/loose.
BMP installed Ken was onsite. No new violations or trackout issues at this time.
|
ESC13-00193
| General Inspection | 2/13/2014 | 2/13/2014 | 2/13/2014 2:35:34 PM | | PEND |
|
|
No construction activity. BMPs are in process of maintenance, recent issues addressed. Wattles were re-trenched and a diverision channel created. No sediment discharges observed. Ground is still thawing and more precipitation is expected this week.
Remaining corrections to lift SWO: 1. Construction entrance 2. Repair silt around project in areas where stockpile has broken stakes. 3. Request ESC inspection for approval
|
ESC14-00043
| Site Preparation | 2/13/2014 | 2/13/2014 | 2/13/2014 2:11:47 PM | P | PASS |
|
|
BMPs including perimeter wattles, downstream check dam, and construction entrance are installed. RP Larry ordered more rock as requested earlier in day. Permit sign will be posted tomorrow AM as agreed to. Approved.
|
ESC13-00761
| Aging Inspection | 2/13/2014 | 2/13/2014 | 2/13/2014 1:47:56 PM | | PASS |
|
|
Finaled.
|
ESC13-00761
| DOC - Permit Finaled | 2/13/2014 | 2/13/2014 | 2/13/2014 1:47:38 PM | P | PASS |
|
|
All exterior work complete. No disturbed earth or stockpiles. No further ESC inspections required. ESC conditions have been met.
|
ESC13-00215
| General Inspection | 2/13/2014 | 2/13/2014 | 2/13/2014 1:13:39 PM | | PASS |
|
|
No sediment leaving culdesac. Individual homes have seperate permits. Minimal tracking due to muddy conditions, but brooms and cleaning equipment onsite. Contractors parking on pavement and not in the open lot. Approved.
|
ESC11-00192
| Random Inspection | 2/13/2014 | 2/13/2014 | 2/13/2014 12:05:40 PM | P | PART |
|
|
Inspection to check hillside erosion.
No new rills or blowouts to street observed. Wattles have been retrenched as requested. Streets are clean mostly, but some sand from road safety operations.
1 new correction:
1. Need to empty DI bags 2. Sweep sidewalks 3. Concrete washout for new homes need to be installed.
|
ESC12-01033
| General Inspection | 2/13/2014 | 2/13/2014 | 2/13/2014 11:55:38 AM | | PASS |
|
|
WIP. Contractors parking on completed driveway. House is nearly done, no landscaping/stabilization yet. Permit posted, no violations observed. Approved
|
ESC13-00524
| BMP Violation | 2/13/2014 | 2/13/2014 | 2/13/2014 11:45:58 AM | A | PEND |
|
|
Initial corrections discussed during conference 2/12 that were able to be completed without accessing muddy lots/hillside with equipment.
Roads were blowouts occured were scraped and cleaned. Some dirt remaining but will be swept as is dries. DI bags that were full were emptied. Upper main drainage inlet was provided with gravel check dams and wattles staked down. Lower rill erosion filled with rock drips to stabilize.
Will continue to monitor as conditions improved for further corrections. Hydroseeding is scheduled to occur next week on areas that are not yet stabilized.
Initial response by contractor is good, but more work needs to be done for full compliance.
|
ESC12-00577
| General Inspection | 2/13/2014 | 2/13/2014 | 2/13/2014 11:27:22 AM | | PASS |
|
|
No changes or activity. BMPs still installed along access road. No corrections required.
|
ESC13-00230
| Random Inspection | 2/13/2014 | 2/13/2014 | 2/13/2014 10:26:58 AM | A | PASS |
|
|
Berm at west end of central area contained runoff and groundwater melt. Perimeter wattles and washout in good condition at this time. Brighton Homes has been told to improved daily house keeping on individual home sites.
|
ESC11-00525
| Random Inspection | 2/13/2014 | 2/13/2014 | 2/13/2014 10:22:16 AM | A | PASS |
|
|
Syman Company on-site doing maintenance of BMPs. No trackout onto roads from sites. Looks good considering the rain and recent thawing. No corrections at this time.
|
ESC13-00745
| Aging Inspection | 2/13/2014 | 2/13/2014 | 2/13/2014 9:40:28 AM | | PASS |
|
|
Yard not landscaped/stabilized but is contained by retaining. Permits were finaled on 12/31 although yard is not complete and some work appears ongoing. Will close ESC permit when landscaped.
|
ESC13-00620
| Aging Inspection | 2/13/2014 | 2/13/2014 | 2/13/2014 9:30:50 AM | | PASS |
|
|
WIP. Permit posted. Some stucco materials on-site in front yard to be hauled away per RP Clint. No other ESC issues.
|
ESC13-00744
| Aging Inspection | 2/13/2014 | 2/13/2014 | 2/13/2014 9:20:18 AM | | PASS |
|
|
All other permits finaled. Interior complete, exterior facia and painting remain. Yard has retaining wall but is not yet stabilized. ESC permit is still posted.
|
ESC09-00352
| General Inspection | 2/13/2014 | 2/13/2014 | 2/13/2014 9:13:05 AM | | PASS |
|
|
No recent activity. No track out to Barber Valley. Brighton is stockpiling dirt on parcel adjacent to park south of the road. Permission was granted under this permit, but any new site work will need new permits, as scheduled work is not in scope of work on this ESC permit. Work is tentatively scheduled for this spring.
|