BLD14-01545 BLD-Footing2/13/20152/13/20152/13/2015 4:25:19 PMPPART
Pouring at 1///Rebar - Mike Phone #: ###-####. Work in progress. Pending special inspection.
BLD13-01820 BLD-Conference2/13/20152/13/20152/13/2015 3:36:07 PMPDONE
BLD14-03583 BLD-Final2/13/20152/13/20152/13/2015 2:41:36 PMPPASS
Please call 30 minutes prior to inspection Thanks Kelly Phone #: ###-#### Inspection requested via web by Brian McCoy
BLD14-03583 DOC - Permit Finaled2/13/20152/13/20152/13/2015 2:41:24 PMPPASS
BLD15-00081 BLD-Final2/13/20152/13/20152/13/2015 2:27:41 PMPNR
Sean Phone #: ###-####
BLD14-03170 BLD-Final2/13/20152/13/20152/13/2015 2:13:22 PMPCANC
Burt Phone #: ###-####
BLD14-03170 BLD-Framing/Rough-in2/13/20152/13/20152/13/2015 2:13:07 PMPPASS
Burt Phone #: ###-####
BLD14-03531 BLD-Ceiling Grid Inspection2/13/20152/13/20152/13/2015 1:35:08 PMPPASS
Brian Phone #: ###-####
BLD15-00209 BLD-Final2/12/20152/13/20152/13/2015 1:34:53 PMPNR
Ron Phone #: ###-####. Needs electrical and life/safety finals.
BLD13-00204 BLD-Final2/13/20152/13/20152/13/2015 12:59:11 PMPPASS
After 10, store not open before - Eric Phone #: ###-####. ok for perm occ. per #301.
BLD14-02997 BLD-Framing/Rough-in2/12/20152/13/20152/13/2015 12:04:57 PMAFAIL
Pat Phone #: ###-####. Nail off all hangars, provide protection for microwave ducts. fireblock at reuturn air upstairs unit, provide adequate strapping on top plates at line sets. Provide truss engineering. Ok to insulate.
BLD14-01590 BLD-Final2/12/20152/13/20152/13/2015 12:02:01 PMAPART
Pat Phone #: ###-####. Will be ok for perm occ once zoning has signed perm.
BLD14-02997 BLD-Wall Bracing2/13/20152/13/20152/13/2015 11:50:51 AMAFAIL
Pat Phone #: ###-####. Install all missing floor to floor straps.
BLD14-02519 BLD-Footing2/12/20152/13/20152/13/2015 11:48:29 AMAPASS
Pat Phone #: ###-####
BLD14-03135 BLD-Framing/Rough-in2/12/20152/13/20152/13/2015 10:54:14 AMAPASS
Keith-please call 1/2 hr prior to meet-Partial Framing-late AM if possible Phone #: ###-####
BLD14-03533 BLD-Final2/12/20152/13/20152/13/2015 10:21:08 AMAPART
Dillion Phone #: ###-####. Ok for temp occ. Needs to provide ADA restroom sign provide flusher on toilet in mens restroom on turning side, Provide a high/low drinking fountain. A racking permit is also required.
BLD14-03400 BLD-Final2/11/20152/13/20152/13/2015 9:37:48 AMADONE
Chris Phone #: ###-####. Met with homeowner, went over homeowners concerns and allsides installation manual. Main areas of concern are corners and window/door openings that may have not been correctly flashed. Also noted two new windows that were installed with no permits. Noted to homeowner to properly asses the work that has been completed, areas of siding would have to be removed for inspection.