Inspections for the day of: Tuesday, February 13, 2018.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-00658 Final2/13/20182/13/20182/13/2018 4:19:41 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC17-05325 Final2/9/20182/13/20182/13/2018 3:54:26 PMPPASS
Please have inspector call Jamie when in route to home ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd
MEC18-00637 Final2/12/20182/13/20182/13/2018 3:34:15 PMPPASS
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC17-01976 Rough-in2/13/20182/13/20182/13/2018 3:12:18 PMPPASS
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover hard lids in units 401, 402, 403, 404, 405, 406
MEC17-04910 Pressure Test2/13/20182/13/20182/13/2018 2:54:36 PMPFAIL
CHRIS IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - Gas piping needs to be burried a minimum of 12" below grade
MEC18-00565 Rough-in2/13/20182/13/20182/13/2018 2:17:33 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak -
Fresh air not per approved manual J's
Ducts not sized per appoved manual J's
Missing insulation shield on b-vent
Insulation shields need 1" gap from b-vent
dryers over 35' in length
Crawls not complete
flue pressure not done on ground floor units
Range vents?
MEC18-00565 Pressure Test2/13/20182/13/20182/13/2018 2:14:11 PMPPART
Phone #: ###-#### Inspection requested via web by Oleg Chervak - 20lb gas pass units B, H. Flue pressure pass units D, E, F, G, H. Gas fail unit G. flue pressure fail units A, B, C.
MEC18-00445 Rough-in2/13/20182/13/20182/13/2018 1:15:51 PMPPASS
Rough-In inspection needed if you have any questions please contact Karl at ###-#### thank you. Phone #: ###-#### Inspection requested via web by Karl Hestekin
MEC18-00588 Final2/13/20182/13/20182/13/2018 12:12:19 PMPPASS
MEC18-00588 Final2/6/20182/13/20182/13/2018 10:36:43 AMAFAIL
CALL KYLE WITH ANY QUESTIONS Phone #: ###-#### Inspection requested via web by Rick Borg - Need combustion air for furnace
MEC18-00588 Pressure Test2/6/20182/13/20182/13/2018 10:36:18 AMAPASS
CALL KYLE WITH ANY QUESTIONS Phone #: ###-#### Inspection requested via web by Rick Borg - 5lb flue
MEC17-01386 Pressure Test2/12/20182/13/20182/13/2018 10:18:24 AMAPASS
Scott Phone #: ###-#### - 20lb gas pass
MEC17-01374 Mec-Aging Inspection2/13/20182/13/20182/13/2018 9:59:23 AM CANC
MEC18-00613 Final2/12/20182/13/20182/13/2018 9:58:28 AMAPASS
Front door code - 8225 Phone #: ###-#### Inspection requested via web by Tim Petsche
MEC18-00445 Rough-in2/12/20182/13/20182/13/2018 8:43:29 AMANR
Rough-In inspection needed for AM if possible if you have any questions please contact Karl at ###-#### thank you. Phone #: ###-#### Inspection requested via web by Karl Hestekin - Not ready, I rescheduled for this afternoon
MEC18-00528 Rough-in2/12/20182/13/20182/13/2018 8:42:50 AMAPART
Contact Name: Trever Jensen Phone #: ###-#### Inspection requested via web by Melissa Kaae - Okay to cover Dryer vent in the wall