Inspections for the day of: Thursday, February 13, 2020.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTell Riley
TitleBLD-COM/RES INSPECTOR
Phone #830-2752
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-01778 BLD-Aging Inspection2/13/20202/13/20202/14/2020 8:30:46 AM DONE
Expires: 03/29/20
BLD18-01781 BLD-Aging Inspection2/13/20202/13/20202/14/2020 8:30:03 AM DONE
Expires: 03/30/20
MIS19-00106 MIS-Aging Inspection2/13/20202/13/20202/14/2020 8:29:27 AM CANC
ESC issues
BLD19-02407 BLD-Footing2/13/20202/13/20202/13/2020 3:52:31 PMPPART
surgeo Phone #: ###-####//heated over night and all day//no frost appears to be present at time of inspection//
BLD20-00137 BLD-Footing2/13/20202/13/20202/13/2020 3:52:12 PMPPART
surgeo Phone #: ###-####//heated over night and all day//no frost appears to be present at time of inspection//
BLD19-02667 BLD-Footing2/13/20202/13/20202/13/2020 3:51:54 PMPPART
surgeo Phone #: ###-####//heated over night and all day//no frost appears to be present at time of inspection//
BLD19-04686 BLD-Final2/11/20202/13/20202/13/2020 3:50:56 PMPPASS
Please call ahead with a time frame. Phone #: ###-#### Inspection requested via web by BRS Permitting
BLD19-04686 DOC - Permit Finaled2/13/20202/13/20202/13/2020 3:50:47 PMPPASS
BLD19-01461 BLD-Final2/13/20202/13/20202/13/2020 3:23:03 PMPCANC
Phone #: ###-#### Inspection requested via web by Jordan Williams//cancel per contactor//
BLD20-00149 BLD-Footing2/13/20202/13/20202/13/2020 2:56:17 PMPNR
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru//need front pin for setback verification//discussed setbacks with Jeff at planning, ok with 3' side and 10' rear//
BLD19-04669 BLD-Foundation2/12/20202/13/20202/13/2020 2:50:01 PMPPART
pat- foundation wall inspection Phone #: ###-####//WIP//will need to cover footings and wall for cold weather protection//
BLD19-04743 BLD-Footing2/12/20202/13/20202/13/2020 12:55:22 PMPPART
Brian Phone #: ###-####//contractor is diging out frost areas and heating with torches onsite//WIP with frost//pour at own risk if frost is not completly removed//areas outside of shade ground temps ok and no frost//
BLD19-00323 BLD-Framing/Rough-in2/12/20202/13/20202/13/2020 10:59:56 AMAPART
call ahead // Kent Phone #: ###-####//insulation installed in existing walls that were open //backing added for accesibility requirements//ok to cover vertical wall ONLY//still need mechanical and fire sprinkler sign offs prior to covering any ceilings//no access to fire riser room--also will need inspected for rated walls and penetrations//
BLD20-00290 BLD-Foundation2/12/20202/13/20202/13/2020 10:05:20 AMAPART
As late as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell //WIP//still need to add vents and grade//footings were not covered last night//advised onsite to cover wall and footings//
BLD19-04026 BLD-Final2/12/20202/13/20202/13/2020 9:50:30 AMAFAIL
Garage door code is 2468 Phone #: ###-#### Inspection requested via web by Joel Hirtle//front step and entry door landing is 8", code maximum in 7 3/4" rise//CN left on kitchen counter//
BLD19-04026 BLD-Blower Door Test Results2/13/20202/13/20202/13/2020 9:49:39 AMADONE
4.01 ACH 50
BLD17-03138 BLD-Final2/12/20202/13/20202/13/2020 9:19:16 AMAPART
LYNDEN Phone #: ###-####//Electircal final complete//building is complete per plans//site plan shows hard surface required for driveway--will need to be installed to complete final//
MIS18-00354 MIS-Aging Inspection2/13/20202/13/20202/13/2020 8:43:03 AM DONE
old permit, no description of unit space
MIS18-00354 DOC - Permit Finaled2/13/20202/13/20202/13/2020 8:42:33 AMPPASS
Expired