Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-00120 Electrical Rough-In2/14/20182/14/20182/14/2018 2:31:57 PMPPASS
We are requesting a wall rough-in inspection for this afternoon for the men''s restroom. Our contact is Bobby ###-####. Thank you, Phone #: ###-#### Inspection requested via web by Clint Tate
Met Curtis with ESI and he informed me existing ceiling to remain with remodel cans being added and 1 recess flourescent turning 90 degrees.
Mens bathroom wall rough in ok cover
ELE18-00561 Temporary Service2/13/20182/14/20182/14/2018 11:01:16 AMAFAIL
Inspect temp power pole. Located next to transformer on the North side of the site. Phone #: ###-#### Inspection requested via web by Tom Jenkins
210.21(B)(1)- A singe receptacle installed on a individual branch circuit shall not have a ampere rating less than that of the branch circuit. 30 amp single receptacle with 40 amp overcurrent protection.
590.6(B)- Receptacles for temp power other than 120 volt shall have GFCI protection.
ELE18-00204 Final2/13/20182/14/20182/14/2018 10:21:34 AMAFAIL
This is a shop, The side man door will be unlocked. If you have any questions please feel free to contact Clay ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clay Morgan
110.27- All NM cable exposed below 8' shall be protected fron physical damage. Back back wall not covered on 1 side.
210.8- All GFCI devices shall be located in a readily accessible location. Horse stall GFI located above 6'7".
* Bathroom floor wet paint no access
ELE18-00549 Temporary Service2/13/20182/14/20182/14/2018 9:48:47 AMAPASS
Phone #: ###-#### Inspection requested via web by Todd Hall
t/s u/g n ok
ELE17-04340 Final2/14/20182/14/20182/14/2018 9:28:25 AMAPASS
code 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ELE17-04355 Final2/14/20182/14/20182/14/2018 9:12:43 AMAPASS
code 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ELE17-04364 Electrical Rough-In2/14/20182/14/20182/14/2018 8:58:46 AMPPASS
Homerun stud bay rough in ok cover