ELE05-00256
| Final | 2/14/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Tina Payne ok to final 2/15/2005 10:06:16 AM
|
ELE04-03417
| Final | 2/14/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 2/14/2005 at 11:37:52 AM. Contact: ###-####. called contr to label subpanels to agree with meters. ok to final 2/15/2005 10:17:38 AM
|
ELE04-02595
| Electrical Rough-In | 2/14/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 2/14/2005 at 12:42:51 PM. Contact: ###-####. 4th fl so bath and soffits ok to cover 2/15/2005 8:32:48 AM
|
ELE04-03618
| Final | 2/14/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | A | PASS |
|
|
Al; Phone #: ###-#### Internet Inspection Request from: Jan Rice corrections made, ok to final 2/15/2005 9:06:44 AM
|
ELE05-00031
| Final | 2/14/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | A | NH |
|
|
need final on kitchen and bathroom Internet Inspection Request from: Andy Rose called contr, he will reschedule 2/15/2005 8:43:40 AM
|
ELE04-04008
| Final | 2/15/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 2/15/2005 at 7:13:40 AM. Contact: ###-####. ok to final 2/15/2005 7:53:03 AM
|
ELE05-00470
| Temporary Service | 2/14/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | A | PASS |
|
|
Internet Inspection Request from: Bob Glenn t/s u/g n ok 2/15/2005 9:36:57 AM
|
ELE04-03914
| Final | 2/14/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | P | NH |
|
|
Scheduled by a contractor via Hello! on 2/14/2005 at 8:24:51 AM. left card, nobody home 2/15/2005 12:07:12 PM
|
ELE05-00084
| Final | 2/15/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | P | PASS |
|
|
Internet Inspection Request from: Bob Glenn called contr, left message. 314.43 nonmetallic box shall not have screws inside, 210.52(D) wash basin shall be within 3' of rcpt, left survey. 2/15/2005 3:22:57 PM
|
ELE05-00135
| Final | 2/15/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | P | PASS |
|
|
Internet Inspection Request from: Bob Glenn ok to final 2/15/2005 4:24:53 PM
|
ELE04-03507
| Electrical Rough-In | 2/15/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | P | FAIL |
|
|
Ceiling inspection for phase 2 cover of ceiling.; Phone #: ###-#### Internet Inspection Request from: Joe Thomas 358.30(A) emt shall be supported within 3' of box, 314.17(A) openings shall be closed (heater), 300.11(A) independent ceiling wires shall be identified, 300.11(2)(B) raceways shall not be used as support for non-electric equipment. Note: support wires for fixtures require min 2 wires for seismic 2/15/2005 2:12:31 PM
|
ELE05-00484
| Final | 2/15/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | P | PASS |
|
|
Please call prior to inspection mike ###-#### ok to final 2/15/2005 12:48:05 PM
|
ELE05-00486
| Rough-In Permanent Service | 2/15/2005 | 2/15/2005 | 2/15/2005 12:00:00 AM | P | PASS |
|
|
###-#### ric ok p/s u/g n ok 2/15/2005 3:10:49 PM
|