Inspections for the day of: Friday, February 15, 2008.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAlan Hauser
TitleMEC-COM/RES INSPECTOR
Phone #794-9453
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC08-00492 Final2/15/20082/15/20082/15/2008 3:26:19 PMPPASS
MEC08-00472 Pressure Test2/15/20082/15/20082/15/2008 2:23:38 PMPPASS
20#
MEC08-00473 Rough-in2/15/20082/15/20082/15/2008 2:23:25 PMPPASS
MEC08-00315 Rough-in2/15/20082/15/20082/15/2008 1:57:42 PMPPASS
4-20#
MEC08-00457 Final2/12/20082/15/20082/15/2008 1:26:11 PMPPASS
MEC08-00457 Rough-in2/12/20082/15/20082/15/2008 1:25:56 PMPPASS
MEC08-00315 Rough-in2/15/20082/15/20082/15/2008 12:16:29 PMPCANC
ext 111 rough in and gas test for the 4 apartments the gas lines are labled with the apt numbers. Phone #: ###-#### Internet Inspection Request from: LINDA DORN Inspection cancelled from web by: LINDA DORN
MEC08-00489 Rough-in2/14/20082/15/20082/15/2008 12:16:05 PMPCANC
Please do gas pressure test at the same time. Thanks. Phone #: ###-#### Internet Inspection Request from: loretta barck Inspection cancelled from web by: LINDA DORN
MEC08-00489 Pressure Test2/14/20082/15/20082/15/2008 12:16:05 PMPCANC
Please do rough-in at the same time. Thanks. Phone #: ###-#### Internet Inspection Request from: loretta barck Inspection cancelled from web by: LINDA DORN
MEC08-00463 Rough-in2/14/20082/15/20082/15/2008 10:40:37 AMAPART
duct ok to cover, have gas leak, installer in process of finding leak, recall for pressure test after lunch.
MEC08-00249 Final2/14/20082/15/20082/15/2008 10:26:21 AMAPASS
MEC08-00412 Pressure Test2/14/20082/15/20082/15/2008 10:03:06 AMAPASS
4-20#
MEC08-00412 Rough-in2/14/20082/15/20082/15/2008 10:02:49 AMAPASS
MEC07-02557 Pressure Test2/13/20082/15/20082/15/2008 9:35:09 AMAPASS
hydronic piping ok for whole system
MEC07-04102 MEC-Aging Inspection2/15/20082/15/20082/15/2008 8:47:22 AM PASS
MEC07-04102 DOC - Permit Finaled2/15/20082/15/20082/15/2008 8:47:14 AMPPASS
MEC08-00489 Pressure Test2/14/20082/15/20082/14/2008 3:08:39 PMACANC
Please do rough in at the same time. Thanks. Phone #: ###-#### Internet Inspection Request from: loretta barck Inspection cancelled from web by: loretta barck
MEC08-00489 Rough-in2/14/20082/15/20082/14/2008 3:08:29 PMACANC
Please do gas pressure test at the same time. Thanks. Phone #: ###-#### Internet Inspection Request from: loretta barck Inspection cancelled from web by: loretta barck