Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD10-02665 BLD-Aging Inspection2/15/20112/15/20112/16/2011 3:12:22 PM CANC
BLD10-01547 BLD-Aging Inspection2/15/20112/15/20112/16/2011 3:07:54 PM CANC
BLD10-02715 BLD-Aging Inspection2/15/20112/15/20112/16/2011 3:06:06 PM CANC
BLD10-02025 BLD-Final2/15/20112/15/20112/15/2011 4:54:11 PMPDONE
>> Inspection requested via web by Stephanie White
BLD10-02025 DOC - Permit Finaled2/15/20112/15/20112/15/2011 4:54:03 PMPPASS
>> Inspection requested via web by Stephanie White
BLD10-02561 BLD-Final2/15/20112/15/20112/15/2011 4:53:19 PMPDONE
>> Inspection requested via web by Stephanie White
BLD10-02561 DOC - Permit Finaled2/15/20112/15/20112/15/2011 4:53:09 PMPPASS
>> Inspection requested via web by Stephanie White
BLD10-02350 BLD-Final2/15/20112/15/20112/15/2011 4:52:41 PMPDONE
>> Inspection requested via web by Stephanie White
BLD10-02350 DOC - Permit Finaled2/15/20112/15/20112/15/2011 4:52:31 PMPPASS
>> Inspection requested via web by Stephanie White
BLD10-02547 BLD-Final2/15/20112/15/20112/15/2011 4:52:12 PMPDONE
>> Inspection requested via web by Stephanie White
BLD10-02547 DOC - Permit Finaled2/15/20112/15/20112/15/2011 4:52:03 PMPDONE
>> Inspection requested via web by Stephanie White
ESC11-00006 Site Preparation2/15/20112/15/20112/15/2011 3:14:35 PMPPASS
ESC permit sign is posted. Spoke to RP about the need for a controlled washout area for concrete. RP noted that he would provide a washout pit for concrete prior to any concrete activities taken place.
BLD11-00019 BLD-Footing2/15/20112/15/20112/15/2011 3:13:04 PMPPASS
Hole location is in the NEC of emtpty lot at Fairview and 5 mile Rd. structural calculations call for a 3'' diameter hole, 11'' deep. Phone #: ###-#### >> Inspection requested via web by Robert Hamlin
BLD11-00020 BLD-Footing2/15/20112/15/20112/15/2011 3:12:47 PMPPASS
hole location is in SWC of the empty lot at Fairview & 5 Mile Rd. Structural calcs call for a 3'' diameter hole, 11'' deep. Phone #: ###-#### >> Inspection requested via web by Robert Hamlin
ESC07-00733 Random Inspection2/15/20112/15/20112/15/2011 2:48:51 PMPPASS
BLD07-01179 BLD-Framing/Rough-in2/15/20112/15/20112/15/2011 2:48:36 PMPPASS
steve Phone #: 891-144. All issues have been resolved. Noted letter from truss designers noting that additional holes for the rough sawn lumber beams would be acceptable.
ESC10-00884 General Inspection2/15/20112/15/20112/15/2011 2:30:12 PMPPART
Nededs to pick up all blowable trash and sweep silts from hardsurfaces. Correction notice was posted.
BLD10-02817 BLD-Framing/Rough-in2/15/20112/15/20112/15/2011 2:29:20 PMPFAIL
rustin Phone #: ###-####. Provide strap at top plate at 4" dryer vent, Foam seal bottom plate at gas pipe penetration, Nail 2ply F3 truss as per truss engineeing, Provide support at bottom of stairs as noted on approved plans. Correction notice posted. ok to insulate.
ESC10-00646 BMP Violation2/15/20112/15/20112/15/2011 11:15:49 AMAPART
Still needs to post ESC permit sign. RP noted that it would be posted today 2-15-11.
BLD10-02011 BLD-Foundation2/14/20112/15/20112/15/2011 11:14:51 AMAPASS
foundation wall insp//Wesley Phone #: ###-####
BLD10-02910 BLD-Conference2/15/20112/15/20112/15/2011 10:23:13 AMPCANC
>> Inspection requested via web by Stephanie White Inspection cancelled from web by: Stephanie White
BLD10-02189 BLD-Conference2/15/20112/15/20112/15/2011 10:20:24 AMPCANC
>> Inspection requested via web by Stephanie White Inspection cancelled from web by: Stephanie White
BLD10-02547 BLD-Conference2/15/20112/15/20112/15/2011 10:19:06 AMPCANC
>> Inspection requested via web by Stephanie White Inspection cancelled from web by: Stephanie White
BLD10-02900 BLD-Framing/Rough-in2/14/20112/15/20112/15/2011 9:20:49 AMANR
DAN Phone #: ###-####. Needs electrical rough in inspections.