ESC08-00407
| Tracking Control | 2/15/2012 | 2/15/2012 | 2/15/2012 5:21:32 PM | A | PASS |
|
|
|
GCB11-00079
| GCB-Final | 2/14/2012 | 2/15/2012 | 2/15/2012 10:47:50 AM | A | FAIL |
|
|
Kris @ ###-####. Needs to provide additional vertical grab bar in ada restroom, provide mirror at required height, lower sink and horizontal grab bars so as to meet ada requirements, provide ada compliant hardware at ada restroom, remove the keyed locking hardware from back door. Provide ada compliant pos.
|
GCB11-00069
| GCB-Shearwall | 2/14/2012 | 2/15/2012 | 2/15/2012 10:12:57 AM | A | PASS |
|
|
Jerry @ ###-####. Exterior shear nail ok. Reviewed and inspected truss repair from truss enginneer for roof trusses that have benn installed upside down. Inspected the 32/16 span rated osb on both sides with required nailing. ok to cover exterior sheathing only.
|
BLD11-01175
| BLD-Final | 2/14/2012 | 2/15/2012 | | P | |
|
|
steve Phone #: ###-####
|