ESC12-01007
| BMP Violation | 2/15/2013 | 2/15/2013 | 2/19/2013 12:00:00 AM | A | FAIL |
|
|
Held conference with Travis Perry (RP) on site. Need to correct housekeeping; clean up illicit washouts; provide washout for mortar and painters; clean/repair all drop inlet BMPs as neccessary; sweep gutter and protect hard surfaces from sediment; post ESC signs for all permitted lots. Also discussed NPDES permit eligibility requirements for disturbances over an acre.
|
ESC12-00918
| BMP Violation | 2/15/2013 | 2/15/2013 | 2/19/2013 12:00:00 AM | A | FAIL |
|
|
Held conference with Travis Perry (RP) on site. Need to correct housekeeping; clean up illicit washouts; provide washout for mortar and painters; clean/repair all drop inlet BMPs as neccessary; sweep gutter and protect hard surfaces from sediment; post ESC signs for all permitted lots. Also discussed NPDES permit eligibility requirements for disturbances over an acre.
|
ESC12-00775
| BMP Violation | 2/15/2013 | 2/15/2013 | 2/19/2013 12:00:00 AM | A | FAIL |
|
|
Held conference with Travis Perry (RP) on site. Need to correct housekeeping; clean up illicit washouts; provide washout for mortar and painters; clean/repair all drop inlet BMPs as neccessary; sweep gutter and protect hard surfaces from sediment; post ESC signs for all permitted lots. Also discussed NPDES permit eligibility requirements for disturbances over an acre.
|
ESC12-01192
| General Inspection | 2/15/2013 | 2/15/2013 | 2/15/2013 2:50:19 PM | P | FAIL |
|
|
Verbal to RP: Drop inlet BMP is not an approved BMP. Construction has encroached into adjacent retention basin; provide sediment barrier along approved limits of distrubance and repair landscaping of retention basin. Move portapot out of ROW. Vehicle tracking to road must be prevented; street sweeping should be used as a supplemental method, not the only method. Topsoil stockpile area on lot close to Boise avenue not permitted for work. Must apply for ESC permit, street sweep sidewalk and gutter and provide perimeter controls. Will create MIS case.
|
ESC12-01081
| General Inspection | 2/15/2013 | 2/15/2013 | 2/15/2013 2:05:32 PM | P | FAIL |
|
|
Verbal to RP: provide concrete washout prior to next pour; clean up concrete washout at entrance and in gutter; clean sediment from gutter; install inlet protection BMP; prevent sediment from entering gutter by limiting parking on dirt along crescent rim; construction entrance on east side no longer effective.
|
MIS13-00034
| ESC-Conference | 2/15/2013 | 2/15/2013 | 2/15/2013 12:00:00 AM | P | FAIL |
|
|
Must apply for ESC permit, street sweep sidewalk and gutter and provide perimeter controls.
|