Inspections for the day of: Friday, February 15, 2019.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Strole
TitlePLM/MEC-INSPECTOR
Phone #794-7913
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM18-04532 Water and/or Sewer2/15/20192/15/20192/15/2019 3:29:58 PMPPASS
PLM18-04532 DOC - Permit Expired2/15/20192/15/20192/15/2019 3:29:50 PMPCANC
PLM18-02007 Final2/15/20192/15/20192/15/2019 3:29:35 PMPPASS
This permit was for rough-in only.
PLM19-00654 Final2/15/20192/15/20192/15/2019 3:27:26 PMPPASS
Michael Phone #: ###-####-This permit was for trim only.
PLM19-00563 Final2/8/20192/15/20192/15/2019 3:04:32 PMPPASS
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
PLM19-00564 Water and/or Sewer2/15/20192/15/20192/15/2019 2:25:14 PMPPASS
Call 15 mins ahead- Chris Phone #: ###-####
MEC18-06108 Rough-in2/15/20192/15/20192/15/2019 2:05:23 PMPPASS
Fireplace Venting changed from straight out back to up and then out. Please re-inspect. Phone #: ###-#### Inspection requested via web by Dan Otero
MEC18-05543 Final2/15/20192/15/20192/15/2019 1:51:46 PMPPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
MEC18-05345 Final2/14/20192/15/20192/15/2019 1:39:53 PMPPASS
field super: Jason Landers
Gate code 7352 Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC18-05102 Final2/14/20192/15/20192/15/2019 1:11:52 PMPPASS
Field super: Jason Landers
Gate code 1957 Phone #: ###-#### Inspection requested via web by Lisa Whitney
PLM18-00304 Final2/13/20192/15/20192/15/2019 11:32:47 AMAFAIL
Phone #: ###-#### Inspection requested via web by Jeffrey Hankins-Need to install a DBCA on water supply for premis protection. Need to install a RPBA on carbonator for soda. Need to install a RPBA on dishwasher. Need to caulk mop sink. Need to use approved material for T&P. Cannot tie T&P and condensate for water heater together. Cannot have pex within 18" of a water heater connection. Need a seperate shutoff valve for water heater.
PLM19-00102 Plumbing Rough-in2/14/20192/15/20192/15/2019 10:39:58 AMAPASS
if questions call Pat @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann
PLM19-00652 Final2/15/20192/15/20192/15/2019 10:02:58 AMAPASS
Call me for information thank you Phone #: ###-#### Inspection requested via web by Brandon Rohricht
PLM19-00646 Water Heater Final2/14/20192/15/20192/15/2019 9:56:30 AMAPASS
Mecanical Permit: MEC19-00659. Please call Tony when on the way ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Jennifer Alcala
PLM17-04916 Final2/14/20192/15/20192/15/2019 9:47:06 AMAPASS
Maureen Phone #: ###-####
MEC19-00593 Rough-in2/14/20192/15/20192/15/2019 9:39:11 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft
MEC18-05097 Final2/14/20192/15/20192/15/2019 8:58:03 AMAPASS
Field super: Jason Landers
gate code 1957 Phone #: ###-#### Inspection requested via web by Lisa Whitney
PLM18-04666 Plumbing Rough-in2/14/20192/15/20192/15/2019 8:35:17 AMAPASS
Phone #: ###-#### Inspection requested via web by Rob Bristol