ELE08-01643
| ELE-Aging Inspection | 2/16/2010 | 2/16/2010 | 2/19/2010 7:46:55 AM | | CANC |
|
|
|
ELE08-01688
| ELE-Aging Inspection | 2/16/2010 | 2/16/2010 | 2/19/2010 7:42:48 AM | | CANC |
|
|
|
ELE09-02481
| Final | 2/16/2010 | 2/16/2010 | 2/17/2010 4:24:58 PM | P | FAIL |
|
|
Tony Phone #: ###-#### called left phone # shall not use a/c, m/c cable, of flex in wet locations
|
ELE09-02481
| Conference | 2/16/2010 | 2/16/2010 | 2/16/2010 4:46:52 PM | P | DONE |
|
|
Tony Phone #: ###-#### called contr ran out of time will do 02-17-10 am
|
ELE09-02482
| Final | 2/16/2010 | 2/16/2010 | 2/16/2010 4:43:07 PM | P | PASS |
|
|
Tony Phone #: ###-#### ok
|
ELE09-02482
| Electrical Rough-In | 2/16/2010 | 2/16/2010 | 2/16/2010 4:42:51 PM | P | PASS |
|
|
Tony Phone #: ###-#### ok needs KO seals 1 each bld N& K
|
ELE10-00272
| Final | 2/12/2010 | 2/16/2010 | 2/16/2010 3:56:15 PM | P | NR |
|
|
Phone #: ###-#### see added r/i request
|
ELE10-00272
| Electrical Rough-In | 2/16/2010 | 2/16/2010 | 2/16/2010 3:55:38 PM | P | FAIL |
|
|
Phone #: ###-#### called corr. and fee due posted 210.63 needs gfci protected WR outside recept with inuse cover
|
ESC10-00044
| General Inspection | 2/16/2010 | 2/16/2010 | 2/16/2010 3:54:02 PM | P | PASS |
|
|
ok sign has no info on it
|
ELE10-00214
| Electrical Rough-In | 2/16/2010 | 2/16/2010 | 2/16/2010 3:15:22 PM | P | PASS |
|
|
restrooms wall ceiling cover Inspection requested from web by: Don Lustig Phone #: ###-#### ok
|
ELE10-00290
| Temporary Service | 2/16/2010 | 2/16/2010 | 2/16/2010 2:31:26 PM | P | FAIL |
|
|
Darrin Phone #: ###-#### called corr. posted needs WR gfci recept, and grd rod driven flush
|
ESC09-00677
| General Inspection | 2/16/2010 | 2/16/2010 | 2/16/2010 1:53:48 PM | P | FAIL |
|
|
needs to clean hard surfaces
|
ELE10-00295
| Electrical Rough-In | 2/16/2010 | 2/16/2010 | 2/16/2010 1:51:34 PM | P | PASS |
|
|
Inspection requested from web by: Dan Rohl Phone #: ###-#### ok
|
ELE10-00287
| Permanent Service | 2/16/2010 | 2/16/2010 | 2/16/2010 1:49:36 PM | P | NR |
|
|
call 1 hour before for access,meter inspection for idaho power Inspection requested from web by: Charles Davis Phone #: ###-#### called told contr requirements for p/s that has been turned off, and IDPCO wants inspection
|
ELE10-00239
| Final | 2/15/2010 | 2/16/2010 | 2/16/2010 12:47:21 PM | A | PASS |
|
|
Please call 1 hour before inspection to meet on site and discause the survey from the rough in inspection. Inspection requested from web by: Emmet Bushman Phone #: ###-#### ok card signed
|
ELE06-04529
| DOC - Permit Expired | 2/16/2010 | 2/16/2010 | 2/16/2010 12:14:10 PM | P | PASS |
|
|
|
ELE06-02440
| DOC - Permit Expired | 2/16/2010 | 2/16/2010 | 2/16/2010 12:13:24 PM | P | PASS |
|
|
|
ELE10-00241
| Electrical Rough-In | 2/13/2010 | 2/16/2010 | 2/16/2010 10:30:57 AM | A | FAIL |
|
|
Inspection requested from web by: Justin Frates Phone #: ###-#### called 300.4 shall provide 11/4" for cables all locations, seal all unused KOs, 517.13 use approved cables or raceways for medical x-ray wiring, note ceiling not ready walls failed do not cover posted
|
ELE08-01083
| Final | 2/10/2010 | 2/16/2010 | 2/16/2010 9:43:19 AM | A | FAIL |
|
|
morgan - please call 1/2 hr prior Phone #: ###-#### needs to update permit for 1 hot tub and up too 20 KW of elect heat, needs inuse covers, gfci for ceiling haeter and garage door opener recepts, only bathrm fan,light, and recept shall be on bath rm 20 amp circuit
|
ELE09-01997
| Electrical Rough-In | 2/15/2010 | 2/16/2010 | 2/16/2010 9:36:59 AM | A | PART |
|
|
Service insp only. Please see Jerry on site - ###-####. Thank you Inspection requested from web by: Tracy Robertson Phone #: ###-#### ok see added p/s
|
ELE09-01997
| Permanent Service | 2/16/2010 | 2/16/2010 | 2/16/2010 9:36:24 AM | A | PASS |
|
|
Service insp only. Please see Jerry on site - ###-####. Thank you Inspection requested from web by: Tracy Robertson Phone #: ###-#### terminate all main bonds and GEC to line side neutral bus p/s u/g new ok
|
ELE10-00026
| Final | 2/15/2010 | 2/16/2010 | 2/16/2010 8:11:05 AM | A | PART |
|
|
Inspection on outlets in open cubicle area before cubicles are installed and access will be limited. Inspection requested from web by: Emmet Bushman Phone #: ###-#### walls ok
|
ELE06-01981
| DOC - Permit Expired | 2/16/2010 | 2/16/2010 | 2/16/2010 7:16:37 AM | A | PASS |
|
|
|
ELE06-02073
| DOC - Permit Expired | 2/16/2010 | 2/16/2010 | 2/16/2010 7:15:50 AM | A | PASS |
|
|
|