Inspections for the day of: Tuesday, February 16, 2016.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-00454 Electrical Rough-In2/16/20162/16/20162/16/2016 1:58:49 PMPPASS
Phone #: ###-#### Inspection requested via web by Don Conley detached garage ok cover
ELE12-03157 ELE-Aging Inspection2/16/20162/16/20162/16/2016 12:19:00 PM CANC
too busy
ELE12-02468 ELE-Aging Inspection2/16/20162/16/20162/16/2016 12:18:36 PM CANC
too busy
ELE16-00320 Final2/15/20162/16/20162/16/2016 12:17:05 PMAPASS
The access code is 8120, please knock first to insure if the customer is home, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren final ok
ELE15-03948 Final2/12/20162/16/20162/16/2016 11:57:43 AMAFAIL
Garage code is 0500 Phone #: ###-#### Inspection requested via web by TOM BICANDI 210.12 AFCI protection required for master bed 210.52 (c)(1) wall counter top spacing shall not be greater the 4' from receptacles (pantry)
ELE15-04113 Electrical Rough-In2/16/20162/16/20162/16/2016 11:33:32 AMAPASS
entry cable heat ok cover
ELE15-04113 Final2/15/20162/16/20162/16/2016 11:30:48 AMAPASS
Installing concrete heat matt, pouring at 9:30 am. Phone #: ###-#### Inspection requested via web by John VanZandt entry heated cable ok cover
ELE16-00432 Rough-In Permanent Service2/12/20162/16/20162/16/2016 11:18:54 AMAFAIL
final and permanent service for cabl tv alpha cabinet at ne corner of 2141 n five mile rd .contact andy ###-####. Phone #: ###-#### Inspection requested via web by andrew dopieralski art.250 need to attach grounding electrode conductor
ELE16-00193 Conference2/15/20162/16/20162/16/2016 10:39:19 AMADONE
Please give Ryan a call before 1/2 hour before arrival. We will not be onsite

Thank you Phone #: ###-#### Inspection requested via web by Thomas Jenkins discussed working clearences for service and and removing exposed knob and tube. Also branch circuits and remoting a panel in down bedroom
ELE15-03219 Electrical Rough-In2/15/20162/16/20162/16/2016 10:08:17 AMAPASS
Contact: Beau Cannon, wall rough-in inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden phase 2 offices walls only ok cover
ELE16-00437 Permanent Service2/13/20162/16/20162/16/2016 9:45:53 AMAFAIL
New Street lighting fixtures ; pedestal Phone #: ###-#### Inspection requested via web by Jerry Moore art 250 grounding electrode system required
ELE16-00357 Electrical Rough-In2/15/20162/16/20162/16/2016 9:31:18 AMAPASS
If you have any questions, please all Matt ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan basement bedroom ok cover
ELE16-00414 Electrical Rough-In2/12/20162/16/20162/16/2016 9:16:34 AMAPASS
The requested items have been repaired and ready for cover thanks Phone #: ###-#### Inspection requested via web by Brad Baker corrections fixed whole house remodel ok cover
ELE16-00435 Temporary Service2/12/20162/16/20162/16/2016 8:54:44 AMAPASS
Phone #: ###-#### Inspection requested via web by Aaron Decker t/s u/g n ok