ELE98-00471
| INSP - Final | 2/17/1998 | 2/17/1998 | 2/18/1998 12:00:00 AM | P | FAIL |
|
|
02/17/98 315 - NU LOOK CAR WASH FOR A VACUUM \###-#### DON cor. posted T 300-5 conduit shall be 24 inches under area subject to veh traffic B.C.C. 4-5-60 vacuum not listed 250-114 EGC shallterminate to disconnect equip. grd bus also bonding jumper
|
ELE98-00474
| INSP - Electrical Rough-In | 2/13/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | A | PART |
|
|
02/17/98 315 - BILL ###-#### R\I P\S..trans by JMS.. cor. posted 210-52 outlets required in kit. right ok pocket door , and in MB left of bathroon door ps ok jf
|
ELE98-00476
| INSP - Final | 2/13/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | A | FAIL |
|
|
02/17/98 315 - ###-####\\SERVICE ONLY 100AMP cor. posted 310-16 provide proper overcurrent protection for conductors, 370-17& BCC 4-5-54 connector for cable j box, 250-81 terminate GEC withi of where metal piping enters house
|
ELE98-00479
| INSP - Final | 2/13/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | A | NH |
|
|
02/17/98 315 - 200 AMP SERVICE nalc
|
ELE97-04023
| INSP - Final | 2/12/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | A | NR |
|
|
02/17/98 315 - WADE ###-####-GET INTO HOUSE CALL ###-####-CHARLIE CONTRA notice posted 210-70 and BCC need to install 2 garage, and 1 outside bac light fixtures
|
ELE97-04446
| INSP - Final | 2/13/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | A | PASS |
|
|
02/17/98 315 - roger ###-#### final ok
|
ELE98-00482
| INSP - Final | 2/13/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | A | FAIL |
|
|
02/17/98 315 - TEMP POLE--ALLEN ###-####--ENTRY CODE TO SUB IS *1776 cor. posted 250-83(c) drive grd rod flush with grade
|
ELE98-00450
| INSP - Final | 2/13/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | A | PASS |
|
|
02/17/98 315 - DON ###-#### HOT TUB ok
|
ELE98-00486
| INSP - Electrical Rough-In | 2/17/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | P | PASS |
|
|
02/17/98 315 - ###-#### EMMITT 18rms 1a/c 200a
|
ELE98-00075
| INSP - Electrical Rough-In | 2/17/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | P | CANC |
|
|
02/17/98 315 - Scheduled by Hello!. Contact phone is [8662162]. no r/i needed final needed see added final inspection request
|
ELE98-00302
| INSP - Final | 2/17/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | P | PASS |
|
|
02/17/98 315 - temporary service steve ###-#### ok
|
ELE98-00316
| INSP - Final | 2/17/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | P | PART |
|
|
02/17/98 315 - ceiling insp debbie ###-#### all ceilings ok for cover no final jf
|
ELE98-00326
| INSP - Final | 2/17/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | P | PASS |
|
|
02/17/98 315 - ###-#### bernice final ok
|
ELE98-00482
| INSP - Final | 2/17/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | P | PASS |
|
|
TEMP ###-#### ALAN ok
|
ELE98-00474
| INSP - Electrical Rough-In | 2/17/1998 | 2/17/1998 | 2/17/1998 12:00:00 AM | P | PASS |
|
|
REINSPECTION ok 12rms 1a/c 200a
|