Inspections for the day of: Wednesday, February 17, 2016.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00084 ELE-Aging Inspection2/17/20162/17/20162/19/2016 2:36:41 PM CANC
ELE13-00091 ELE-Aging Inspection2/17/20162/17/20162/19/2016 2:36:23 PM CANC
ELE12-00936 ELE-Aging Inspection2/17/20162/17/20162/19/2016 2:35:58 PM CANC
ELE15-03734 Final2/16/20162/17/20162/17/2016 3:42:13 PMPPASS
contact: Gary ###-#### Phone #: ###-#### Inspection requested via web by Tracy Robertson Final ok
ESC15-00070 General Inspection2/17/20162/17/20162/17/2016 3:15:31 PM PASS
Minor dirt on parking areas due to landscape work. No major issues
ELE16-00262 Final2/17/20162/17/20162/17/2016 3:02:29 PMPPASS
Mike Phone #: ###-#### or Jared ###-#### Wiring for loovers remains but has been disconnected. Final ok
ELE13-00104 Final2/17/20162/17/20162/17/2016 3:01:24 PMPPASS
Mike Phone #: ###-#### or Jared ###-#### Lighting retro final ok
ELE16-00474 Final2/17/20162/17/20162/17/2016 2:28:39 PMPCANC
Service in the back. Temp box will be the one to the east. This will be heated up for temp power. Please call. Phone #: ###-#### Inspection requested via web by Greg Idsinga
Needed temp service inspection
ELE16-00474 Temporary Service2/17/20162/17/20162/17/2016 2:28:24 PMPFAIL
Service in the back. Temp box will be the one to the east. This will be heated up for temp power. Please call. Phone #: ###-#### Inspection requested via web by Greg Idsinga
110.7- Temp service for clean up and testing of roof top units. When tested some circuits still connected to circuit breakers showed no resistance when turned on. Disconnect all existing breakers and test and reconnect when supervised.
ELE15-03948 Final2/17/20162/17/20162/17/2016 1:26:36 PMPPASS
Garage code is 0500 Phone #: ###-#### Inspection requested via web by TOM BICANDI Final ok
ELE15-03579 Final2/16/20162/17/20162/17/2016 10:35:00 AMAFAIL
Phone #: 6311362 >> Inspection requested via mobile web by Mike
Owner installed floor heat in baths on main floor and basement without having inspected. Not having removed but shall have GFCI protection as per NEC 210.8
ELE15-03712 Electrical Rough-In2/16/20162/17/20162/17/2016 10:01:09 AMAPASS
This is a rough inspection only of the office. Phone #: ###-#### Inspection requested via web by Paula Gratiot
Offica area only rough in ok cover
ELE15-03117 Electrical Rough-In2/16/20162/17/20162/17/2016 9:33:44 AMAPASS
ceiling Inspection, Greg Milburn is contact at ###-####. thank you. Phone #: ###-#### Inspection requested via web by Debby Pierce
couple fixtures damaged in shipping contractor to leave grid open where missing are located. Grid rough in ok cover
ELE16-00432 Final2/16/20162/17/20162/17/2016 9:06:18 AMAPASS
inspection for final and permanent service .grounding conductor connected .contact # 8694390 andy . Phone #: ###-#### Inspection requested via web by andrew dopieralski Final ok
ELE16-00432 Permanent Service2/17/20162/17/20162/17/2016 9:06:05 AMPPASS
inspection for final and permanent service .grounding conductor connected .contact # 8694390 andy . Phone #: ###-#### Inspection requested via web by andrew dopieralski p/s u/g n ok