ELE12-00227
| ELE-Aging Inspection | 2/17/2017 | 2/17/2017 | 2/23/2017 12:04:36 PM | | DONE |
|
|
still waiting for contractor to schedule...2nd attempt at contacting
|
ELE16-01924
| Conference | 2/17/2017 | 2/17/2017 | 2/17/2017 2:11:44 PM | P | PASS |
|
|
Micah Phone #: ###-####....
discussed new service to feed new panel for existing house circuits and panel for new addition....using existing recessed meter main and converting into junction box....new meter with main breaker on outside to feed new panels..explained could not have unfused conductors in wall...explored various options
|
ELE17-00388
| Permanent Service | 2/17/2017 | 2/17/2017 | 2/17/2017 12:37:52 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan McLaughlin....
p/s o/h rec ok
|
ELE17-00394
| Final | 2/16/2017 | 2/17/2017 | 2/17/2017 12:18:15 PM | P | PASS |
|
|
Call Miles with questions. ###-#### Phone #: ###-#### Inspection requested via web by Sheri Berry....
ok to final
|
ELE17-00057
| Final | 2/16/2017 | 2/17/2017 | 2/17/2017 11:44:14 AM | P | NR |
|
|
Final inspection please. Thank you. Phone #: ###-#### Inspection requested via web by Kyle Lott....
will call back in for monday 2/20/17
|
ELE17-00266
| Electrical Rough-In | 2/16/2017 | 2/17/2017 | 2/17/2017 11:08:11 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rowdy Monroe...
rough ok to cover check for intersystem bond at sevice at final p/s u/g n ok
|
ELE17-00267
| Electrical Rough-In | 2/16/2017 | 2/17/2017 | 2/17/2017 11:06:55 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rowdy Monroe...
rough ok to cover check for intersystem bond at final at service p/s u/g n ok
|
ELE17-00400
| Conference | 2/16/2017 | 2/17/2017 | 2/17/2017 10:17:44 AM | A | PASS |
|
|
Bryan Phone #: ###-####...
discussed whats needed to be done for rough in inspection...nailplating, stapling of wires...flat not on side...replace wire that sheathing been cut...remove old wiring...safe off existing wiring/proove not energized...ARC fault protection of all openings in bedroom-smoke detector, light, outlets....tamper resistant outlets to be installed
|
ELE17-00265
| Final | 2/10/2017 | 2/17/2017 | 2/17/2017 9:32:30 AM | A | PASS |
|
|
Insta hot circuit installed. Phone #: ###-#### Inspection requested via web by Randy Fletcher..
ok to final
|
ELE17-00195
| Electrical Rough-In | 2/17/2017 | 2/17/2017 | 2/17/2017 9:10:47 AM | A | PASS |
|
|
Please Sean Crawley call prior to arrival for access. Floor heat installation. Phone #: ###-#### Inspection requested via web by Patrick Paz....
ok to cover
|
ELE16-03455
| Final | 2/16/2017 | 2/17/2017 | 2/17/2017 8:48:15 AM | A | FAIL |
|
|
Garage code 7530 Phone #: ###-#### Inspection requested via web by Darryn Coburn..
1) exposed romex at furnace...334.15(B) 2) entry closet light to close to shelf...410.16(C) 3) exhaust fan in master shower shall have GFI protection...UL listing...110.3
|