Inspections for the day of: Tuesday, February 18, 2014.
Number of inspections: 36
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Strole
TitlePLM/MEC-INSPECTOR
Phone #794-7913
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC14-00663 Final2/17/20142/18/20142/18/2014 3:45:43 PMPPASS
Installing 2/18, please call Jimmy w/TML before going, thank you Phone #: ###-#### >> Inspection requested via web by Michele LaMott
MEC14-00554 Pressure Test2/18/20142/18/20142/18/2014 3:44:54 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by April Thomas-20 lb gas test to range fail, 20 lb gas test to fireplace passed.
MEC14-00554 Rough-in2/18/20142/18/20142/18/2014 3:43:13 PMPPASS
Phone #: ###-#### >> Inspection requested via web by April Thomas
PLM14-00359 Plumbing Rough-in2/18/20142/18/20142/18/2014 2:33:04 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Jeff Coate
PLM14-00360 Plumbing Rough-in2/18/20142/18/20142/18/2014 2:32:40 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Jeff Coate
MEC14-00472 Pressure Test2/18/20142/18/20142/18/2014 2:18:57 PMPFAIL
basement is unfinished, regulators will not be covered. thank you Any questions please call jed Phone #: ###-#### >> Inspection requested via web by Gary Reeves-60 lb pressure test fail.(tested thru all regulators. Remove and test and then replace all regulators.)
MEC14-00472 Rough-in2/18/20142/18/20142/18/2014 2:17:00 PMPFAIL
basement is unfinished, regulators will not be covered. thank you Any questions please call jed Phone #: ###-#### >> Inspection requested via web by Gary Reeves-Need jump duct, make-up air on both furnaces, manual-j needs to match duct work, need to test furnace and water heater flues, how many cfm is the kitchen exhaust?
MEC14-00474 Rough-in2/18/20142/18/20142/18/2014 2:12:03 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Debbie Marino-Rough-in not complete, heat sheild and duct work to complete.
PLM14-00339 Water Heater Final2/13/20142/18/20142/18/2014 12:58:43 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Todd Vitek
PLM14-00048 Final2/18/20142/18/20142/18/2014 12:49:30 PMPPASS
Please call Johnny when on the way. ###-####. Thank you. Phone #: ###-#### >> Inspection requested via web by Jennifer Alcala
MEC14-00301 Final2/18/20142/18/20142/18/2014 12:48:22 PMPPASS
Call Matt at ###-#### with any questions. Phone #: ###-#### >> Inspection requested via web by Angie Maguire
PLM14-00176 Final2/14/20142/18/20142/18/2014 11:41:01 AMAFAIL
JOB CONTACT - MEL ###-#### Phone #: ###-#### >> Inspection requested via web by BECCA DUMMER-Need to test dbca, need airgap on T&P and need to caulk shower trim.
PLM14-00309 Plumbing Rough-in2/17/20142/18/20142/18/2014 11:02:46 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Scott Hurren
MEC13-05114 Final2/14/20142/18/20142/18/2014 10:54:28 AMAPASS
>> Inspection requested via web by Jason Robinson
MEC14-00540 Rough-in2/17/20142/18/20142/18/2014 10:45:36 AMAPASS
Call Jason @ ###-#### with any inspection issues. Phone #: ###-#### >> Inspection requested via web by Angie Maguire
MEC14-00540 Pressure Test2/17/20142/18/20142/18/2014 10:45:16 AMAPASS
Call Jason @ ###-#### with any inspection issues. Phone #: ###-#### >> Inspection requested via web by Angie Maguire-20 lb gas test pass
MEC14-00614 Conference2/14/20142/18/20142/18/2014 10:44:39 AMACANC
Phone #: ###-#### >> Inspection requested via web by Dan Otero
MEC14-00594 Rough-in2/14/20142/18/20142/18/2014 10:44:11 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Dan Otero-Need standoffs on top of fireplace for clearance per manufacture installations.
PLM13-03460 Final2/17/20142/18/20142/18/2014 10:23:46 AMAPASS
Call for garage code: ###-#### or ###-#### Phone #: ###-#### >> Inspection requested via web by David Stephenson
MEC13-05391 Final2/12/20142/18/20142/18/2014 10:23:28 AMAPASS
Call Clint for garage access ###-#### Phone #: ###-#### >> Inspection requested via web by Mike Almanza
PLM13-03495 Final2/17/20142/18/20142/18/2014 10:23:07 AMAPASS
Call for garage code: ###-#### or ###-#### Phone #: ###-#### >> Inspection requested via web by David Stephenson
MEC14-00649 Final2/18/20142/18/20142/18/2014 10:01:22 AMPCANC
1:00 PM
MEC14-00649 Final2/17/20142/18/20142/18/2014 10:01:04 AMPCANC

need to call customer for access sarah silva
we did job on monday Phone #: ###-#### >> Inspection requested via web by Dustin Rich
MEC14-00649 Pressure Test2/17/20142/18/20142/18/2014 9:58:46 AMACANC
p/t is for flue
need to call customer for access sarah silva
we did job on monday Phone #: ###-#### >> Inspection requested via web by Dustin Rich-Changed inspection to 2-29-14 PM
MEC14-00480 Rough-in2/14/20142/18/20142/18/2014 9:56:35 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Debbie Marino-No test on flue and rough-in not complete.
MEC14-00480 Pressure Test2/14/20142/18/20142/18/2014 9:55:09 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Debbie Marino-20 lb pressure test pass
MEC13-05177 Final2/12/20142/18/20142/18/2014 9:54:24 AMAPASS
call Braxton for garage code ###-#### Phone #: ###-#### >> Inspection requested via web by Mike Almanza
MEC13-05093 Final2/14/20142/18/20142/18/2014 9:54:04 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Debbie Marino-Need to install kitchen exhaust
MEC14-00474 Rough-in2/14/20142/18/20142/18/2014 9:26:31 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Debbie Marino-Rough-in not complete
MEC14-00474 Pressure Test2/14/20142/18/20142/18/2014 9:25:46 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Debbie Marino-20 lb pressure test and 5 psi flue test pass.
PLM14-00087 Final2/17/20142/18/20142/18/2014 8:54:03 AMAPEND
final on new ADA restrooms and new back flow valve in the main water line Phone #: ###-#### >> Inspection requested via web by Anderson Kenny-Will final when mechanical permit is issued.
MEC13-04617 Final2/17/20142/18/20142/18/2014 8:15:37 AMAPASS
CALL CHRIS FOR ENTRY AT ###-#### Phone #: ###-#### >> Inspection requested via web by Jason Robinson
PLM13-01711 PLM-Aging Inspection2/18/20142/18/20142/18/2014 7:27:16 AM PEND
no calls
PLM13-02619 PLM-Aging Inspection2/18/20142/18/20142/18/2014 7:26:26 AM PEND
no calls
MEC13-00831 DOC - Permit Finaled2/18/20142/18/20142/18/2014 7:25:44 AMAPASS
MEC14-00614 Conference2/14/20142/18/20142/14/2014 11:44:30 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Dan Otero Inspection cancelled from web by: Dan Otero