Inspections for the day of: Tuesday, February 18, 2020.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-00382 Rough-in2/17/20202/18/20202/18/2020 4:09:42 PMPPASS
Call when you are on the way so we can meet you there. Phone #: ###-#### Inspection requested via web by Dan McFate
- 20lb gas pressure test ok
- R/I ok hvac and fireplace
MEC19-04420 Final2/17/20202/18/20202/18/2020 3:31:41 PMPPASS
AC: 9165 Phone #: ###-#### Inspection requested via web by Gary Reeves
- final ok
MEC20-00589 Final2/17/20202/18/20202/18/2020 3:11:51 PMPNH
Please call ahead to Bruce when headed to residence Phone #: ###-#### Inspection requested via web by Sarah Small
- no access to home
MEC20-00591 Final2/17/20202/18/20202/18/2020 3:11:38 PMPNH
Call ahead to Bruce when headed to residence Phone #: ###-#### Inspection requested via web by Sarah Small
- no access to home
MEC20-00685 Rough-in2/18/20202/18/20202/18/2020 3:11:12 PMPFAIL
Please call contractor 30 minutes in advance for access at ###-#### and call Ryan with questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum
- all b vent needs 1" clearances
- need to see insulation sheild in attic
- furnace connection to common vent needs to connect at bottom of b vent wye and water heater needs to connect at the highest point in the b vent wye
- range hood is a 600 cfm and will need make up air or be under 400 cfm
MEC20-00653 Rough-in2/18/20202/18/20202/18/2020 1:59:34 PMPFAIL
Phone #: ###-#### Inspection requested via web by Jose Lagunas
- need approved ManJ onsite
- line set needs R/I
- gas gauge would not zero
- 5lb flue test needs to be on a 15lb gauge
- water heater bvent does not fit into 2x4 wall
- supply cans in floor above garage need insulated
- combustion air openings are not big enough for water heater and furnace
MEC20-00673 Final2/17/20202/18/20202/18/2020 1:26:35 PMPPASS
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- furnace ac coil co ok
MEC19-02406 Final2/17/20202/18/20202/18/2020 11:15:29 AMAPASS
Christine is available at 9am, if at all possible complete the inspection around that timeframe. Tech will be onsite. Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- furnace ac coil co ok
MEC20-00347 DOC - Permit Finaled2/18/20202/18/20202/18/2020 10:58:12 AMPPASS
final ok
MEC20-00347 Rough-in2/18/20202/18/20202/18/2020 10:57:51 AMAPASS
Two vents Phone #: ###-#### Inspection requested via web by Andrew Knight
- R/I ok
MEC20-00534 Final2/13/20202/18/20202/18/2020 10:43:18 AMAPASS
PLEASE CALL HOMEOWNER MIKE WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery
- furnace only co ok
MEC20-00608 Final2/14/20202/18/20202/18/2020 10:34:46 AMACANC
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney
- should have been a R/I
MEC20-00608 Rough-in2/18/20202/18/20202/18/2020 10:34:35 AMAPASS
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney
- R/I ok
MEC20-00652 Final2/17/20202/18/20202/18/2020 10:33:13 AMAPASS
Homeowner Sandie Rolof ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace only co ok
MEC20-00491 Rough-in2/14/20202/18/20202/18/2020 9:54:25 AMAFAIL
Please call Mike when on the way. Thank you!! Phone #: ###-#### Inspection requested via web by Denise Colin
- Man J needs updated for furnace and approved by City
- bathroom exhausts need finished
- line set arma flex in crawl needs repaired
- all bedrooms will need transfer air or ducted returns by final
- all floor boots need sealed
- need to add duct work and exhaust fans to permit
MEC20-00638 Final2/14/20202/18/20202/18/2020 9:11:48 AMAPASS
Homeowners David ; Molly Bird ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace ac coil co ok
MEC20-00602 Final2/12/20202/18/20202/18/2020 9:10:35 AMAFAIL
Homeowner Jeff Graham ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace b vent needs 1" clearances and vent connector needs 1/4 slope
- A/C coil co ok
MEC20-00663 Pressure Test2/17/20202/18/20202/18/2020 8:45:02 AMAPASS
Please call Jerrie on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- 20lb gas pressure test ok
- tagged meter location
- sharp bend in line set below furnace needs fixed before arma flex cover
- furnace access is in bathroom all combustion needs taken from the outdoors and access door will need to be sealed and self closing for final