MEC20-00382
| Rough-in | 2/17/2020 | 2/18/2020 | 2/18/2020 4:09:42 PM | P | PASS |
|
|
Call when you are on the way so we can meet you there. Phone #: ###-#### Inspection requested via web by Dan McFate - 20lb gas pressure test ok - R/I ok hvac and fireplace
|
MEC19-04420
| Final | 2/17/2020 | 2/18/2020 | 2/18/2020 3:31:41 PM | P | PASS |
|
|
AC: 9165 Phone #: ###-#### Inspection requested via web by Gary Reeves - final ok
|
MEC20-00589
| Final | 2/17/2020 | 2/18/2020 | 2/18/2020 3:11:51 PM | P | NH |
|
|
Please call ahead to Bruce when headed to residence Phone #: ###-#### Inspection requested via web by Sarah Small - no access to home
|
MEC20-00591
| Final | 2/17/2020 | 2/18/2020 | 2/18/2020 3:11:38 PM | P | NH |
|
|
Call ahead to Bruce when headed to residence Phone #: ###-#### Inspection requested via web by Sarah Small - no access to home
|
MEC20-00685
| Rough-in | 2/18/2020 | 2/18/2020 | 2/18/2020 3:11:12 PM | P | FAIL |
|
|
Please call contractor 30 minutes in advance for access at ###-#### and call Ryan with questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum - all b vent needs 1" clearances - need to see insulation sheild in attic - furnace connection to common vent needs to connect at bottom of b vent wye and water heater needs to connect at the highest point in the b vent wye - range hood is a 600 cfm and will need make up air or be under 400 cfm
|
MEC20-00653
| Rough-in | 2/18/2020 | 2/18/2020 | 2/18/2020 1:59:34 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Jose Lagunas - need approved ManJ onsite - line set needs R/I - gas gauge would not zero - 5lb flue test needs to be on a 15lb gauge - water heater bvent does not fit into 2x4 wall - supply cans in floor above garage need insulated - combustion air openings are not big enough for water heater and furnace
|
MEC20-00673
| Final | 2/17/2020 | 2/18/2020 | 2/18/2020 1:26:35 PM | P | PASS |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - furnace ac coil co ok
|
MEC19-02406
| Final | 2/17/2020 | 2/18/2020 | 2/18/2020 11:15:29 AM | A | PASS |
|
|
Christine is available at 9am, if at all possible complete the inspection around that timeframe. Tech will be onsite. Phone #: ###-#### Inspection requested via web by Andrea Grigsby - furnace ac coil co ok
|
MEC20-00347
| DOC - Permit Finaled | 2/18/2020 | 2/18/2020 | 2/18/2020 10:58:12 AM | P | PASS |
|
|
final ok
|
MEC20-00347
| Rough-in | 2/18/2020 | 2/18/2020 | 2/18/2020 10:57:51 AM | A | PASS |
|
|
Two vents Phone #: ###-#### Inspection requested via web by Andrew Knight - R/I ok
|
MEC20-00534
| Final | 2/13/2020 | 2/18/2020 | 2/18/2020 10:43:18 AM | A | PASS |
|
|
PLEASE CALL HOMEOWNER MIKE WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery - furnace only co ok
|
MEC20-00608
| Final | 2/14/2020 | 2/18/2020 | 2/18/2020 10:34:46 AM | A | CANC |
|
|
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney - should have been a R/I
|
MEC20-00608
| Rough-in | 2/18/2020 | 2/18/2020 | 2/18/2020 10:34:35 AM | A | PASS |
|
|
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney - R/I ok
|
MEC20-00652
| Final | 2/17/2020 | 2/18/2020 | 2/18/2020 10:33:13 AM | A | PASS |
|
|
Homeowner Sandie Rolof ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace only co ok
|
MEC20-00491
| Rough-in | 2/14/2020 | 2/18/2020 | 2/18/2020 9:54:25 AM | A | FAIL |
|
|
Please call Mike when on the way. Thank you!! Phone #: ###-#### Inspection requested via web by Denise Colin - Man J needs updated for furnace and approved by City - bathroom exhausts need finished - line set arma flex in crawl needs repaired - all bedrooms will need transfer air or ducted returns by final - all floor boots need sealed - need to add duct work and exhaust fans to permit
|
MEC20-00638
| Final | 2/14/2020 | 2/18/2020 | 2/18/2020 9:11:48 AM | A | PASS |
|
|
Homeowners David ; Molly Bird ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok
|
MEC20-00602
| Final | 2/12/2020 | 2/18/2020 | 2/18/2020 9:10:35 AM | A | FAIL |
|
|
Homeowner Jeff Graham ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace b vent needs 1" clearances and vent connector needs 1/4 slope - A/C coil co ok
|
MEC20-00663
| Pressure Test | 2/17/2020 | 2/18/2020 | 2/18/2020 8:45:02 AM | A | PASS |
|
|
Please call Jerrie on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - 20lb gas pressure test ok - tagged meter location - sharp bend in line set below furnace needs fixed before arma flex cover - furnace access is in bathroom all combustion needs taken from the outdoors and access door will need to be sealed and self closing for final
|