Inspections for the day of: Wednesday, February 19, 2014.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01757 ELE-Aging Inspection2/19/20142/19/20142/24/2014 9:44:01 AM DONE
see doc expire
ELE14-00186 Final2/19/20142/19/20142/19/2014 3:18:09 PMPPASS
Bob Johnston @ ###-#### Phone #: ###-#### >> Inspection requested via web by Kristopher Wilson ok final
ELE13-02358 Final2/19/20142/19/20142/19/2014 2:59:19 PMPPART
Partial final for Owner Occupancy Phone #: ###-#### >> Inspection requested via web by Bryan Atkins north 1/2 building only ok final, signed t/o card
ELE14-00327 Temporary Service2/19/20142/19/20142/19/2014 2:39:01 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
ELE14-00328 Temporary Service2/19/20142/19/20142/19/2014 1:52:40 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
ELE14-00326 Temporary Service2/19/20142/19/20142/19/2014 1:31:20 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
ELE13-03390 Electrical Rough-In2/18/20142/19/20142/19/2014 12:54:54 PMPPASS
ROUGH IN FOR PHASE TWO Phone #: ###-#### >> Inspection requested via web by MARK PINNEY walls only ok cover
ELE14-00242 Electrical Rough-In2/19/20142/19/20142/19/2014 12:12:19 PMPNR
David Phone #: ###-#### shall finish stapling, make-up, free conductor length, will re-call
ELE14-00314 Rough-In Permanent Service2/18/20142/19/20142/19/2014 10:40:10 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Bob Glenn ri ok, p/s u/g n ok
ELE14-00372 Temporary Service2/18/20142/19/20142/19/2014 10:16:02 AMAPASS
Temp power inspection. Any questions please contact Lonny. Phone #: ###-#### >> Inspection requested via web by Vicki Moore t/s o/h n ok
ELE14-00033 Final2/18/20142/19/20142/19/2014 9:58:39 AMAPASS
joe Phone #: ###-#### ok final
ELE14-00384 Permanent Service2/18/20142/19/20142/19/2014 9:08:14 AMAPASS
call Art with questions Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack p/s o/h rec ok, 2 meters req'd
ELE14-00371 Electrical Rough-In2/18/20142/19/20142/19/2014 8:34:45 AMAFAIL
Back garage door will be opened Phone #: ###-#### >> Inspection requested via web by daniel bibikov called, left correction notice, NEC 300.4(A)(1) shall use nailplates for bored holes if edge of hole less than 1 1/4" from edge of framing member, 358.26 raceway system shall not have more than 360 degree total bend without pull point, 250.56 shall use 2 ground rods, 230.2 building shall be supplied by only 1 service, BCC no violations shall be retained, ri inspection requires that no devices sahll be installed
ELE14-00321 Final2/18/20142/19/20142/19/2014 7:54:02 AMAPASS
Call if you have any questions Phone #: ###-#### >> Inspection requested via web by Thomas wilson ok final
ELE14-00327 Temporary Service2/18/20142/19/20142/18/2014 2:37:45 PMACANC
Phone #: ###-#### >> Inspection requested via web by Alan Lusk Inspection cancelled from web by: Alan Lusk