ELE12-01757
| ELE-Aging Inspection | 2/19/2014 | 2/19/2014 | 2/24/2014 9:44:01 AM | | DONE |
|
|
see doc expire
|
ELE14-00186
| Final | 2/19/2014 | 2/19/2014 | 2/19/2014 3:18:09 PM | P | PASS |
|
|
Bob Johnston @ ###-#### Phone #: ###-#### >> Inspection requested via web by Kristopher Wilson ok final
|
ELE13-02358
| Final | 2/19/2014 | 2/19/2014 | 2/19/2014 2:59:19 PM | P | PART |
|
|
Partial final for Owner Occupancy Phone #: ###-#### >> Inspection requested via web by Bryan Atkins north 1/2 building only ok final, signed t/o card
|
ELE14-00327
| Temporary Service | 2/19/2014 | 2/19/2014 | 2/19/2014 2:39:01 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
|
ELE14-00328
| Temporary Service | 2/19/2014 | 2/19/2014 | 2/19/2014 1:52:40 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
|
ELE14-00326
| Temporary Service | 2/19/2014 | 2/19/2014 | 2/19/2014 1:31:20 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
|
ELE13-03390
| Electrical Rough-In | 2/18/2014 | 2/19/2014 | 2/19/2014 12:54:54 PM | P | PASS |
|
|
ROUGH IN FOR PHASE TWO Phone #: ###-#### >> Inspection requested via web by MARK PINNEY walls only ok cover
|
ELE14-00242
| Electrical Rough-In | 2/19/2014 | 2/19/2014 | 2/19/2014 12:12:19 PM | P | NR |
|
|
David Phone #: ###-#### shall finish stapling, make-up, free conductor length, will re-call
|
ELE14-00314
| Rough-In Permanent Service | 2/18/2014 | 2/19/2014 | 2/19/2014 10:40:10 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Bob Glenn ri ok, p/s u/g n ok
|
ELE14-00372
| Temporary Service | 2/18/2014 | 2/19/2014 | 2/19/2014 10:16:02 AM | A | PASS |
|
|
Temp power inspection. Any questions please contact Lonny. Phone #: ###-#### >> Inspection requested via web by Vicki Moore t/s o/h n ok
|
ELE14-00033
| Final | 2/18/2014 | 2/19/2014 | 2/19/2014 9:58:39 AM | A | PASS |
|
|
joe Phone #: ###-#### ok final
|
ELE14-00384
| Permanent Service | 2/18/2014 | 2/19/2014 | 2/19/2014 9:08:14 AM | A | PASS |
|
|
call Art with questions Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack p/s o/h rec ok, 2 meters req'd
|
ELE14-00371
| Electrical Rough-In | 2/18/2014 | 2/19/2014 | 2/19/2014 8:34:45 AM | A | FAIL |
|
|
Back garage door will be opened Phone #: ###-#### >> Inspection requested via web by daniel bibikov called, left correction notice, NEC 300.4(A)(1) shall use nailplates for bored holes if edge of hole less than 1 1/4" from edge of framing member, 358.26 raceway system shall not have more than 360 degree total bend without pull point, 250.56 shall use 2 ground rods, 230.2 building shall be supplied by only 1 service, BCC no violations shall be retained, ri inspection requires that no devices sahll be installed
|
ELE14-00321
| Final | 2/18/2014 | 2/19/2014 | 2/19/2014 7:54:02 AM | A | PASS |
|
|
Call if you have any questions Phone #: ###-#### >> Inspection requested via web by Thomas wilson ok final
|
ELE14-00327
| Temporary Service | 2/18/2014 | 2/19/2014 | 2/18/2014 2:37:45 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Alan Lusk Inspection cancelled from web by: Alan Lusk
|