ELE15-02825
| Final | 2/17/2016 | 2/19/2016 | 2/19/2016 2:34:49 PM | P | FAIL |
|
|
Semir Phone #: ###-#### 210.8- All receptacle outlets serving kitchen counter top areas shall have GFCI protection. 406.12(A)- All new 15 and 20 amp 120 volt receptacle outlets shall be tamper resistant type. Called and left message
|
ELE16-00502
| Electrical Rough-In | 2/18/2016 | 2/19/2016 | 2/19/2016 1:53:34 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by PAT MILLER Ceiling only living rm, back wall and fireplace in family rm, m. bed lighting, all m. bath with future floor heat. Rough in ok cover
|
ELE16-00439
| Final | 2/18/2016 | 2/19/2016 | 2/19/2016 1:37:36 PM | P | PASS |
|
|
HOME OWNER WILL BE HOME. Phone #: ###-#### Inspection requested via web by Garrett Collins Final ok
|
ELE13-01272
| ELE-Aging Inspection | 2/19/2016 | 2/19/2016 | 2/19/2016 1:10:03 PM | | FAIL |
|
|
300.15- Where conduit, tubing, AC, MC, NM, or other cable is used a box shall be installed at each splice point. Where old sign was on building.
|
ELE15-03328
| Electrical Rough-In | 2/19/2016 | 2/19/2016 | 2/19/2016 12:24:49 PM | P | PASS |
|
|
Phone #: ###-#### IMC installed underground and to change to PVC just above ground to box. Bonding of IMC to be in ground box where conduit all originate. Underground rough in ok cover.
|
ELE16-00183
| Final | 2/19/2016 | 2/19/2016 | 2/19/2016 12:08:27 PM | P | PASS |
|
|
Mike Phone #: ###-#### Final ok
|
ELE13-01333
| ELE-Aging Inspection | 2/19/2016 | 2/19/2016 | 2/19/2016 11:34:15 AM | | PASS |
|
|
Waiting on contractor
|
ELE12-00227
| ELE-Aging Inspection | 2/19/2016 | 2/19/2016 | 2/19/2016 11:22:34 AM | | PASS |
|
|
Waiting on contractor
|
ELE16-00488
| Rough-In Permanent Service | 2/18/2016 | 2/19/2016 | 2/19/2016 11:09:40 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
|
ELE15-04053
| Final | 2/18/2016 | 2/19/2016 | 2/19/2016 10:45:36 AM | A | PASS |
|
|
Garage Code 2020 E Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
ELE15-03899
| Final | 2/18/2016 | 2/19/2016 | 2/19/2016 10:03:47 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn 314.21- Drywall shall be repaired where boxes moved around windows so gap around box does not exceed 1/8". 314.25- Box in ceiling of back patio shall have a cover. 400.8(2)- Flexible cords shall not be run through walls. Power supply cord for LED drivers.
|
ELE16-00498
| Final | 2/18/2016 | 2/19/2016 | 2/19/2016 8:44:18 AM | A | PASS |
|
|
final and permanent service for cable tv power supply. alpha cabinet .se corner of 10600 Tahiti and n. fivemile rd. contact ####-#### .Andy Phone #: ###-#### Inspection requested via web by andrew dopieralski Final ok
|
ELE16-00498
| Permanent Service | 2/19/2016 | 2/19/2016 | 2/19/2016 8:27:43 AM | P | PASS |
|
|
final and permanent service for cable tv power supply. alpha cabinet .se corner of 10600 Tahiti and n. fivemile rd. contact ####-#### .Andy Phone #: ###-#### Inspection requested via web by andrew dopieralski p/s u/g n ok
|