BLD19-04993
| BLD-Footing | 2/19/2020 | 2/19/2020 | 2/19/2020 3:03:08 PM | P | PART |
|
|
|
BLD20-00115
| BLD-Foundation | 2/18/2020 | 2/19/2020 | 2/19/2020 2:53:05 PM | P | PASS |
|
|
As early as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell
|
BLD20-00481
| BLD-Footing | 2/19/2020 | 2/19/2020 | 2/19/2020 2:00:34 PM | P | PASS |
|
|
|
BLD18-04520
| BLD-Framing/Rough-in | 2/19/2020 | 2/19/2020 | 2/19/2020 2:00:21 PM | A | PASS |
|
|
Energy Seal, Fire Caulking ; Framing Building 11 - Tower 1. Phone #: ###-#### Inspection requested via web by Bob Goodwin
|
BLD18-03240
| BLD-Final | 2/19/2020 | 2/19/2020 | 2/19/2020 1:38:02 PM | P | PASS |
|
|
Cody- please call for access Phone #: ###-####
|
BLD18-03240
| DOC - Permit Finaled | 2/19/2020 | 2/19/2020 | 2/19/2020 1:37:54 PM | P | PASS |
|
|
|
BLD19-04916
| BLD-Framing/Rough-in | 2/18/2020 | 2/19/2020 | 2/19/2020 10:24:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Todd Landvatter. Interior steel stud framed walls ok for cover. Hardlids will be ok for cover pending fire sprinkler and mech. rough in inspections.
|
BLD19-02532
| BLD-Final | 2/18/2020 | 2/19/2020 | 2/19/2020 9:56:16 AM | A | PASS |
|
|
Contact Betty Kaufman (HomeOwner) Alternate Contact: Frank Kaufman (Spouse) ###-#### Alternate 2: Bonnie Carrow ###-#### Phone #: ###-#### Inspection requested via web by Bonnie Carrow
|
BLD19-02532
| DOC - Permit Finaled | 2/19/2020 | 2/19/2020 | 2/19/2020 9:56:08 AM | P | PASS |
|
|
|
BLD19-03192
| BLD-Wall Bracing | 2/18/2020 | 2/19/2020 | 2/19/2020 9:44:23 AM | A | PASS |
|
|
shear // Nathan Phone #: ###-####
|
BLD20-00050
| BLD-Wall Bracing | 2/18/2020 | 2/19/2020 | 2/19/2020 8:59:41 AM | A | NR |
|
|
Inspection requested via web by Rob Ashworth
|
BLD20-00335
| BLD-Other | 2/18/2020 | 2/19/2020 | 2/19/2020 8:45:08 AM | A | DONE |
|
|
Inspection on a completed asphalt roof installation. Phone #: ###-#### Inspection requested via web by Michael La Pointe
|
BLD20-00335
| DOC - Permit Finaled | 2/19/2020 | 2/19/2020 | 2/19/2020 8:44:56 AM | P | PASS |
|
|
All work appeared to be done in accordance with local codes and ordinaces.
|
BLD20-00481
| BLD-Footing | 2/18/2020 | 2/19/2020 | 2/19/2020 8:44:04 AM | A | FAIL |
|
|
Gali Phone #: ###-####. Footings to be 12 inch deep min. per enginering. Also noted footing subgrade is frozen.
|
BLD19-04993
| BLD-Footing | 2/18/2020 | 2/19/2020 | 2/19/2020 8:24:34 AM | A | FAIL |
|
|
Sammie Phone #: ###-####. footing subgrade frozen. Concrete contractor will uncover footings to let thaw. Will reinspect in the pm.
|